This multicenter study supports the accuracy of LD CT for stone identification in noninfected obese patients across BMI subgroups, with ULD CT best reserved for patients with BMI 30-35 kg/m2.
Abstract
Objective
To evaluate the diagnostic accuracy of low-dose (LD) and ultra-low-dose (ULD) computed tomography (CT) scan for stone identification in obese patients compared to conventional-dose CT.
Methods
A review of patients undergoing CT scans for kidney or ureteral stones at two academic institutions was conducted. Patients with body mass index (BMI) >30 kg/m2 and both a conventional and LD CT within 100 days of each other were included. LD was defined as <4 millisieverts (mSv) and ULD as <1.9 mSv. Renal units with interval treatment or documented stone passage were excluded. CTs were reviewed by board-certified radiologists.
Results
Fifty-two patients met inclusion criteria with mean BMI of 36.2 kg/m2 (range: 30.2-63.8). The combined average effective dose of LD and ULD CT was significantly lower than conventional CT (2.3 vs 14.9 mSv; p<0.001), an 85% reduction. LD and ULD CT detected 92/96 stones >2 mm (96% sensitivity) and 95/115 stones overall (83% sensitivity). All stones missed were ≤4 mm in size. LD CT BMI-stratified analysis demonstrated 100% sensitivity for stones >2 mm for BMI 30-35 and >40 kg/m2, and 90% for BMI 35-40 kg/m2. ULD CT demonstrated 100% sensitivity for stones >2 mm for BMI 30-35 kg/m2.
Conclusion
Overall, LD and ULD CT in obese patients accurately identified stones >2 mm with 96% sensitivity, while reducing radiation dose by 85%. This multicenter study supports the accuracy of LD CT for stone identification in noninfected obese patients across BMI subgroups, with ULD CT best reserved for patients with BMI 30-35 kg/m2.
LD PCCT serves as a radiation-sparing alternative for quantitative disease assessment, with total disease burden showing good agreement with the SD protocol, offering a radiation-sparing alternative without compromising CT-physiology correlation.
Zhen-Chen Zhu, Ke-Pei Xu, Yi-Yun Pang et al.· European Radiology· 0 citations
Skeletal radiography remains the primary imaging method for multiple myeloma (MM) included in the clinical protocol of the Republic of Belarus, but its low sensitivity increases the risk of false–negative results and delayed therapy initiation, which is associated with additional costs of treating progressive disease.O...
A. Domantsevich, I. Nazarenko· Medical and Biological Probl...· 0 citations
AIM
To evaluate the safety and fluorescence performance of an ultra-low-dose, short-interval indocyanine green (ICG) protocol in pediatric fluorescence guided surgery (FGS), and to compare dose and timing with pediatric publications.
METHODS
A multicenter retrospective analysis of prospectively collected data from pe...
S. Prodan, Cecilia Gigena Heitsman, J. Udaquiola et al.· Journal of Pediatric Surgery· 0 citations
ABSTRACT
Introduction. Diagnostic reference levels (DRLs) are essential tools for optimizing radiation dose in computed tomography (CT) imaging, yet many countries lack national benchmarks. This study aimed to establish local DRLs for adult brain CT examinations in Jordan and to compare them with international standar...
Ehab Ababneh, Ahmad Abu Alfwares· HEALTH RESEARCH IN AFRICA· 0 citations
OBJECTIVE
To evaluate an optimized CT enterography (CTE) strategy combining reduced radiation exposure and iodine administration in patients with Crohn's disease (CD), with subjective image quality as the primary endpoint.
METHODS
This prospective single-center randomized study enrolled 102 patients with CD who under...
Hou-Qiang Chen, B. Tang, Jia Li et al.· European Journal of Radiolog...· 0 citations