Abstract
Grid voltage unbalance is one of the major issues affecting the power quality of modern distribution systems due to uneven load distribution, the integration of distributed energy resources, and grid disturbances. This condition may reduce the reactive power compensation performance and the DC-link voltage stability of a Static Synchronous Compensator (STATCOM). This paper presents a quantitative evaluation of the impact of grid voltage unbalance severity on the performance of a three-phase STATCOM. The model is developed in the MATLAB/Simulink environment using a synchronous reference frame control method combined with PI controllers. Four voltage unbalance levels corresponding to voltage unbalance factors (VUFs) of 0%, 2%, 4%, and 6% are investigated. System performance is evaluated in terms of the reactive power of the source and the STATCOM, compensation effectiveness, power factor, and DC-link voltage fluctuation. Simulation results show that as the VUF increases, the reactive power compensation capability of the STATCOM decreases, while the reactive power supplied by the source and the DC-link voltage fluctuation increase, and the power factor decreases. The research results provide a reference for the evaluation, design, and operation of STATCOMs under unbalanced grid conditions.
The quality of power in medium-voltage distribution grids has become increasingly challenging due to the growing penetration of variable renewable energy sources and the increasing presence of unbalanced loads. Variable distributed generation introduces generation ramps at the Point of Common Coupling (PCC), causing ra...
Igor S. Rodrigues, A. D. Espindola, Silvangela L. Barcelos et al.· Eletrônica de Potência· 0 citations
The operating performance of wind electric generators has considerable stress on the quality of electric power and reliability in the performance power systems [1]. Power quality issues such as voltage dip, harmonic distortion and reliability problems are main considerations in this work. The voltage distortion & react...
K.Prathibha, K.Madhavilatha· Journal of Science & Technol...· 0 citations
This paper presents a measurement-validated power quality assessment of a grid-connected wind farm in Jordan based on synchronized field measurements and validated simulation studies. The increasing penetration of large-scale wind farms into modern power systems introduces significant power quality challenges, particul...
Malik K. Alkasasbeh, B. Ismail, C. Charin et al.· Electrica· 0 citations
A fixed-proportion load shedding scheme with fixed-parameter reactive power compensation can barely maintain voltage under weak disturbances. Once the output of new energy sources fluctuates drastically, the adaptive matching control strategy cannot be implemented, resulting in poor transient voltage control stability...
Yun-Ling Sun, Hua-Long Li, Xin-Ke Hang et al.· Journal of Physics, Conferen...· 0 citations
In the distribution side of electrical power systems, especially in industries, the non-linear and sensitive loads are increasing day by day, due to which the power quality (PQ) is degrading. The main PQ issues are voltage sags, reactive power imbalance, and harmonics, which are primarily addressed by advanced power el...
Voltage stability is increasingly important in modern power systems due to rising network
complexity, higher power demands, widespread integration of large generation units and long
distance transmission lines. The bus voltage magnitude tends to decrease continuously due to
disturbances and can cause voltage collapse...
A. B. Ogundare· International Journal of Eng...· 0 citations