Skip to content
Conference Open access

Power Quality Assessment of Grid-Connected Photovoltaic Systems in Buildings with Distributed Renewable Energy

Sep 2026 · Journal of Physics, Conference Series · Vol 3321, pp. 012011 · 1 citation · 4 references
Physics

Abstract

The increasing penetration of distributed renewable energy sources, particularly grid-connected photovoltaic (PV) systems, has introduced new challenges related to the quality and stability of electrical power in low-voltage distribution networks. Buildings equipped with distributed generation units often integrate both single-phase and three-phase PV inverters, which may influence voltage stability, harmonic distortion, phase balance, and overall power quality in the electrical installation. As photovoltaic capacity continues to expand in urban and institutional buildings, systematic assessment of power quality parameters becomes essential to ensure compliance with international standards and reliable operation of electrical infrastructure. This paper presents an experimental investigation of power quality characteristics in a building equipped with distributed photovoltaic generation connected to a three-phase low-voltage electrical system. The analyzed installation includes both single-phase and three-phase PV systems with a nominal capacity of 10 kW each. Measurements were carried out using a Class-A power quality analyzer compliant with IEC 61000-4-30 measurement standards. The monitoring campaign was conducted over an extended period under different operating conditions, including periods without photovoltaic generation, partial generation, and peak solar production. The study focuses on the evaluation of key power quality indicators such as voltage magnitude variations, frequency stability, harmonic distortion, voltage unbalance, and power factor. Particular attention is given to the impact of single-phase photovoltaic inverters on phase voltage asymmetry within the three-phase building supply network. The obtained results are compared against the limits specified in international standards such as EN 50160 and IEEE 519. The measurement results reveal that photovoltaic generation can lead to noticeable variations in phase voltage levels, particularly in cases where single-phase PV systems inject power asymmetrically into the distribution network. Under high solar generation conditions, localized voltage rise and increased phase voltage imbalance were observed. Furthermore, harmonic distortion associated with inverter operation was analyzed through spectral decomposition and total harmonic distortion (THD) evaluation.

Read PDF

Similar papers

Review Open access 2026

Power Quality in Grid-Connected Photovoltaic Inverters: A Systematic Review of Critical Parameters, Standards, and Mitigation Strategies

The rapid integration of grid-connected photovoltaic (PV) systems has intensified concerns regarding power quality (PQ) driven by the widespread deployment of power electronic inverters and the increasing intermittency of operating environmental conditions. In this context, a comprehensive characterization of the criti...

Cristopher García-Uzca, D. Ochoa-Correa · 1 citation
Open access Sep 2026

Measurement-Validated Power Quality Assessment and Static Synchronous Compensator–Based Mitigation of a Grid-Connected Wind Farm

This paper presents a measurement-validated power quality assessment of a grid-connected wind farm in Jordan based on synchronized field measurements and validated simulation studies. The increasing penetration of large-scale wind farms into modern power systems introduces significant power quality challenges, particul...

Malik K. Alkasasbeh, B. Ismail, C. Charin et al. · 0 citations
Open access Oct 2026

Stability-Constrained Multi-Objective Dispatch of PV–Battery Inverters for Harmonic Suppression and Voltage Unbalance Compensation in Low-Voltage Distribution Networks

The rapid growth of rooftop photovoltaic (PV) generation and battery energy storage is increasing the number of power-electronic inverters connected to low-voltage distribution networks, creating both new power-quality challenges and an opportunity to use existing converter capacity more intelligently. Harmonic distort...

Elgammal Adel · 0 citations
Open access Sep 2026

Power factor performance analysis of PV-integrated institutional buildings using capacitor banks and synchronous condensers

The increasing deployment of building-scale photovoltaic (PV) systems can influence power factor (PF) performance in electrical distribution networks, especially when reactive power demand is not properly compensated. Poor PF can increase apparent power demand, reduce distribution system efficiency, and expose consumer...

M. Amirudin, Elia Erwani Hassan, Z. M. Yasin et al. · 0 citations
Open access Sep 2026

Coordinated Control of Grid Integrated PV–Battery Architecture for Overvoltage Mitigation in High-PV Distribution Networks

The exponential integration of distributed energy resources (DERs), particularly solar photovoltaic (PV) systems, into low-voltage (LV) distribution networks has introduced critical challenges regarding voltage stability. In high-impedance feeders with low $X / R$ ratios, excessive PV generation during light-load perio...

Piyusha Kukade, Prashant Surana, Amit Kumar et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.