Skip to content
Open access

Readout Electronics Firmware for the Beam Particle Monitor in the HIRFL-CSR External-Target Experiment

Oct 2026 · IEEE Transactions on Nuclear Science · Vol 73, pp. 3824-3836 · 0 citations · 40 references

Abstract

The cooler-storage-ring (CSR) external-target experiment (CEE) at the Heavy Ion Research Facility in Lanzhou (HIRFL) requires a non-interceptive beam particle monitor (BPM) for accurate primary vertex reconstruction and background suppression. Traditional beam diagnostics fail to meet the simultaneous requirements of high spatial resolution, continuous online monitoring, and radiation hardness, so a dual micro time projection chamber (micro-TPC) BPM based on a custom Topmetal-CEEv2 pixel application-specific integrated circuit (ASIC) is developed here. This work presents a full field-programmable gate array (FPGA) readout firmware running on three Xilinx Kintex-7 devices, featuring modular control, trigger synchronization, and multi-stage data processing. Three operation modes are supported: raw data mode, trigger-synchronized scientific data mode, and a novel four-stage pipelined online tracking mode for real-time centroid calculation, whose multi-cluster capability has been validated through guard-ring injection tests. The pipelined logic yields a fixed latency of <inline-formula> <tex-math notation="LaTeX">$1.9\ \mu \text {s}$ </tex-math></inline-formula> and cuts data throughput to only 10% of raw pixel streams, greatly reducing data acquisition (DAQ) load. We validate the system via guard-ring pulse injection, <inline-formula> <tex-math notation="LaTeX">$4\times 4$ </tex-math></inline-formula> pinhole laser tests and <inline-formula> <tex-math notation="LaTeX">$350\ \text {MeV/u}$ </tex-math></inline-formula> heavy-ion beam experiments. After <inline-formula> <tex-math notation="LaTeX">$3\sigma $ </tex-math></inline-formula> outlier elimination, centroid standard deviations drop from <inline-formula> <tex-math notation="LaTeX">$7.47/2.88$ </tex-math></inline-formula> to <inline-formula> <tex-math notation="LaTeX">$0.47/0.46$ </tex-math></inline-formula> at two laser injection positions. Beam campaigns prove the BPM satisfies the design targets: transverse spatial resolution better than <inline-formula> <tex-math notation="LaTeX">$50\ \mu \text {m}$ </tex-math></inline-formula> and time resolution below <inline-formula> <tex-math notation="LaTeX">$1\ \mu \text {s}$ </tex-math></inline-formula>. Compared with our incomplete Topmetal-CEEv1 prototype firmware, this version integrates pipelined trigger acquisition, remote quickboot and real-time status monitoring, with higher throughput and mode flexibility. All test results verify the complete and stable performance of the proposed BPM readout firmware.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.