Seismic deformation and post-earthquake stability assessment of a slope-building system
Abstract
Time-history-based seismic assessment of slope-building systems remains limited, with most previous studies relying mainly on factor-of-safety based or simplified evaluations. This study addresses that gap through three-dimensional nonlinear numerical analyses of a site-specific slope–building system. The free-vibration characteristics of the building were first identified, and the initial static deformation field under self-weight and structural loading was then established. Five spectrum-compatible ground motions, scaled to the Design Basis Earthquake target spectrum for Kırşehir, were used in the time-history analyses. The peak (transient) total displacement increased from 0.099 m in the static condition to 0.139-0.402 m under seismic loading, while the post-earthquake factor of safety decreased from 1.69 to 1.16-1.18. Principal strain (ε₁) contours, plastic point accumulation, tension cut-off zones, and uz/H cumulative distribution functions show that failure is governed by combined shear and tensile mechanisms. The findings demonstrate the need for mechanism-based seismic assessment beyond factor of safety alone.