Seismic deformation and post-earthquake stability assessment of a slope-building system

Oct 2026 · Scientific Reports · Vol 16 · 0 citations · 47 references

Abstract

Time-history-based seismic assessment of slope-building systems remains limited, with most previous studies relying mainly on factor-of-safety based or simplified evaluations. This study addresses that gap through three-dimensional nonlinear numerical analyses of a site-specific slope–building system. The free-vibration characteristics of the building were first identified, and the initial static deformation field under self-weight and structural loading was then established. Five spectrum-compatible ground motions, scaled to the Design Basis Earthquake target spectrum for Kırşehir, were used in the time-history analyses. The peak (transient) total displacement increased from 0.099 m in the static condition to 0.139-0.402 m under seismic loading, while the post-earthquake factor of safety decreased from 1.69 to 1.16-1.18. Principal strain (ε₁) contours, plastic point accumulation, tension cut-off zones, and uz/H cumulative distribution functions show that failure is governed by combined shear and tensile mechanisms. The findings demonstrate the need for mechanism-based seismic assessment beyond factor of safety alone.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.