Oct 2026· European Heart Journal· Vol 47· 0 citations
TL;DR
Comparable long-term survival was observed between SAA and No-SAA patients supporting the safety and effectiveness of TAVI in patients with SAA, and significant LV reverse remodeling and systolic functional improvement occur after TAVI regardless of aortic valve annular size.
Abstract
Transcatheter aortic valve implantation (TAVI) has become standard of treatment for severe aortic stenosis patients with high or intermediate risk. Limited and controversial data are available on the impact of having a small aortic valve annulus (SAA) on left ventricular (LV) remodeling and clinical outcomes after TAVI.
To evaluate the changes in LV remodeling and function after TAVI in patients with and without SAA and to compare their mortality after intervention.
Patients who underwent TAVI between September 2011 and December 2021 and had available CT-derived aortic valve annular area data, as well as both baseline and follow-up echocardiographic assessments, were included and divided into:SAA Group: AV annular area ≤430 mm²;No-SAA group: AV annular area >430 mm².
Baseline echocardiography was performed at a median of 1 day (range 1–73 days) before the TAVI procedure, while follow-up echocardiography was conducted at a median of 192 days (range 185–206 days) after the intervention. All-cause mortality was assessed during long-term follow-up.
A total of 500 patients (46 % women; median age 81 years) were included, of whom 168 had SAA (34%). Patients with SAA were predominantly female (80%) and had lower prevalence of coronary artery disease and atrial fibrillation (Table). Balloon-expandable valves were less frequently used in the SAA group.
At baseline, no difference in LV remodeling patterns were observed between the groups (p = 0.497). However, higher baseline LV ejection fraction (LVEF) (p=0.012) and global longitudinal strain (LVGLS) (p=0.031) were observed in the SAA group, along slightly smaller LV mass and volumes.
At post-TAVI follow-up, residual mean AV pressure gradient was slightly higher in the SAA group (p=0.004), while stroke volume index was similar in both groups. Regardless of annular size, LVEF and LVGLS significantly improved, as also LV mass and end-systolic volume (p<0.05). The group-by-time interaction was not statistically significant for LVEF (p = 0.092), LVGLS (p = 0.076), LV mass index (p = 0.906) or end-systolic volume index (p = 0.703), suggesting similar patterns of left ventricular reverse remodeling across the groups.
During a median follow-up of 74 months, 200 patients (40%) experienced all-cause death. Long-term mortality was similar between the SAA and No-SAA groups (39% vs. 40%). Kaplan–Meier curve analyses showed no significant difference in all-cause mortality between groups (log-rank P=0.727, Figure).
Significant LV reverse remodeling and systolic functional improvement occur after TAVI regardless of aortic valve annular size. Comparable long-term survival was observed between SAA and No-SAA patients supporting the safety and effectiveness of TAVI in patients with SAA.
Aortic stenosis is highly prevalent in the elderly population, and transcatheter aortic valve implantation (TAVI) is increasingly used for symptomatic severe disease. While left heart remodeling after TAVI has been extensively studied, the prognostic implications of right atrial (RA) functional adaptation remain...
K. Guzman, M. Minchala, F. Islas et al.· European Heart Journal· 0 citations
BACKGROUND
Patients with small aortic annuli undergoing transcatheter aortic valve implantation (TAVI) are at risk of higher residual transvalvular gradients. Evidence on the performance of new-generation intra-annular self-expanding valves in this anatomical setting remains limited.
AIMS
To evaluate the impact of an...
M. Casenghi, S. Corradetti, P. Paolisso et al.· Catheterization and cardiova...· 0 citations
Aortic stenosis is typically associated with a progressive concentric hypertrophic response of the left ventricular (LV) myocardium. However, an asymmetric pattern of LV remodeling observed in some patients has been associated with earlier LV decompensation, more rapid progression to valve replacement, and an ove...
A. Chwała, J. Kwieciński, A. Pylko et al.· European Heart Journal· 0 citations
Patients with small aortic annuli undergoing transcatheter aortic valve implantation (TAVI) are at risk of higher residual transvalvular gradients. Evidence on the performance of new-generation intra-annular self-expanding valves in this anatomical setting remains limited. We evaluated the impact of annular size...
J. Capparelli, M. Casenghi, S. Corradetti et al.· European Heart Journal· 0 citations
Mitral regurgitation (MR) is a prevalent valvular disease, and mitral transcatheter edge-to-edge repair (M-TEER) is recommended for patients with severe MR who are inoperable or at high surgical risk. While M-TEER has shown comparable outcomes to conventional surgery, over 10% of patients experience mortality, an...
R. Mistrulli, I. R. Ilaria Rubino, T. S. Tatyana Storozhenko et al.· European Heart Journal· 0 citations
Bicuspid aortic valve (BAV) is a leading cause of aortic stenosis (AS) in younger patients. Recently, the anatomical understanding of BAV has increased, and BAV subtypes are known to also be found in calcific aortic stenosis of the elderly. With the expansion of transcatheter aortic valve replacement (TAVR) into...
M. Kirchner, F. L. Lutilsky, F. Bergmann et al.· European Heart Journal· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.