Oct 2026· International Journal of Particle Therapy· Vol 22, pp. 101967· 0 citations· 32 references
Medicine
TL;DR
The proposed framework provides a foundation for next-generation automated treatment planning systems and motivates future extension to patient-specific, clinically realistic scenarios.
Abstract
Purpose This study presents the proof-of-concept of a novel framework for fully automated proton therapy treatment planning that enables the simultaneous optimization of all major beam parameters, including fluences, energies, and field orientations, within a single differentiable programming approach. The objective is to overcome current limitations of conventional treatment planning systems, which restrict optimization to fluence alone. Materials and Methods A differentiable deep-learning (DL) dose engine based on Graph Neural Networks was employed to emulate Monte Carlo (MC) dose deposition of proton pencil beams with millisecond inference time and high accuracy. The model predicts energy deposition within a cylindrical scoring volume around each beam, which is subsequently mapped to the CT reference frame using differentiable geometric transformations and interpolation. Exploiting end-to-end differentiability, exact gradients of dose with respect to beam energies, orientations, and fluences were computed and used for plan optimization. A hybrid strategy combining Covariance Matrix Adaptation Evolution Strategy (CMA) for global exploration and the Adam gradient-based optimizer for local refinement was implemented. Proof-of-concept evaluations were conducted in homogeneous water phantom geometries and in a head-and-neck phantom CT featuring single- and dual-field configurations targeting a defined planning target volume while sparing organs at risk. Results The DL dose engine reproduced high-statistics MC simulated dose distributions with mean relative errors of the order of percent, with a computational efficiency compatible with iterative optimization. The joint optimization procedure reliably converged from random initial conditions to reproducible solutions in both single- and dual-field setups, generating clinically meaningful Spread-Out Bragg peaks with homogeneous planning target volume coverage and effective organs at risk sparing. Conclusion This work demonstrates the feasibility of fully joint, gradient-based optimization of all key proton therapy beam parameters using a differentiable DL dose engine. The proposed framework provides a foundation for next-generation automated treatment planning systems and motivates future extension to patient-specific, clinically realistic scenarios.
LaDose is presented, a latent diffusion framework for fully volumetric dose prediction, trained so that perturbed latents decode to plausible doses, compresses dose maps 128-fold and enables 3D diffusion on a single GPU.
J. Boyer-Chammard, R. Vauclin, M. Biston et al.· 0 citations
The clinical feasibility of the proposed HALO framework for cervical cancer radiotherapy in producing high‐quality and deliverable IMRT plans is demonstrated, demonstrating that the proposed automated paradigm can serve as a stand‐alone platform for treatment planning.
Hai-Yan Jiang, Zeng-Tai Yuan, Zi-Hao Liu et al.· Journal of Applied Clinical...· 0 citations
This work replaces the standard MSE training objective with a differentiable $\gamma$-index-based loss, extended to native 3D operation, and demonstrates that directly optimising the clinical evaluation metric yields a mean Gamma Passing Rate that is critical for clinical deployment.
J. Jawaid, M. Spezialetti, Gabriele Libardi et al.· 0 citations
Machine learning (ML) models for normal tissue complication probability (NTCP) can be embedded directly into inverse treatment planning, but the resulting optimization problems are generally nonconvex, and the choice between global and local optimization involves a trade-off between optimality guarantees and computatio...
T. Ortkamp, Florian Leininger, Zhong-Xing Liao et al.· 0 citations
Abstract Background Carbon ion radiotherapy (CIRT) offers superior dose conformity and biological effectiveness; however, its precision is highly sensitive to respiratory motion, leading to dose uncertainty and interplay effects that compromise treatment accuracy. Methods A comprehensive literature synthesis was conduc...
Jian-Hua Ding, Peng Li, C. H. Yeong· Journal of Applied Clinical...· 0 citations