TL;DR
Under the conditions of this in vitro study, fit assessment method influenced measured gap values and comparisons among tested FDPs, with limited quantitative interchangeability between alternative and conventional methods.
Abstract
Objectives
To assess the fit of additively and subtractively manufactured zirconia fixed dental prostheses (FDPs) using different evaluation methods and compare alternative methods with the conventional method.
Methods
Three-unit FDPs were fabricated additively from zirconia slurry (AM) or subtractively from highly translucent (SM-HT) or strength-gradient zirconia (SM-SG) (n = 15 per group). Fit was assessed using digital (modified triple-scan), semi-digital (three-dimensional [3D] and two-dimensional [2D] silicone replica), and conventional silicone replica methods. Gap values were analyzed using a linear mixed-effects model and Bonferroni-corrected post hoc comparisons. Agreement and proportional bias between each alternative method and the conventional method were evaluated separately within each material using Bland-Altman and simple linear regression analyses, respectively (α = 0.05).
Results
Material, assessment method, and their interaction affected measured gaps (P < 0.001). AM FDPs showed greater gaps than subtractively manufactured FDPs with the 3D and conventional silicone replica methods, while the 3D method yielded the highest values within each material (P < 0.001). Bland-Altman analysis revealed material-dependent biases. Significant proportional bias was detected for modified triple-scan across all materials (negative, P < 0.001), 2D silicone replica in AM and SM-SG (negative, P ≤ 0.002), and 3D silicone replica only in SM-HT (positive, P = 0.001).
Conclusions
Measured gap values and comparisons among tested FDPs depended on the assessment method. Group mean gap values exceeded the designed cement space. Intermethod biases varied by material and assessment method.
CLINICAL
Significance
Under the conditions of this in vitro study, fit assessment method influenced measured gap values and comparisons among tested FDPs, with limited quantitative interchangeability between alternative and conventional methods. Combining marginal and internal adaptation into overall gap values limits clinical interpretation. Measured values do not establish clinical acceptability or long-term prosthetic success.
OBJECTIVES
To evaluate the effect of additive and subtractive manufacturing workflows on the fit accuracy of inlay-retained fixed partial dentures (IRFPDs) using three-dimensional (3D) analysis.
METHODS
Standardized inlay preparations were performed on typodont mandibular second premolar and molar abutments, and digi...
I. Kader, Simge Dagistan, Elif Nur Köroğlu et al.· E -journal of dentistry· 0 citations
PURPOSE
The purpose of this in vitro study was to compare the marginal and internal fit of ceramic-filled resin crowns fabricated using subtractive manufacturing (SM) and additive manufacturing (AM) techniques and to evaluate the effect of stereolithography (SLA) and digital light processing (DLP) technologies on resto...
Egem Yuvanç, Funda Akaltan, M. Ocak et al.· Australian dental journal· 0 citations
Background: Accurate three-dimensional (3D) recording of implant positions is fundamental to achieving passive fit and long-term success of implant-supported prostheses. The growing adoption of digital intraoral scanners (IOS) necessitates rigorous clinical evaluation of their accuracy relative to established conventio...
Rahul Ranjan, Anju Aggarwal, Punit R. S. Khurana et al.· International Journal of Dru...· 0 citations
This study aimed to compare the three-dimensional trueness of digital impressions with conventional impressions for maxillary complete dentures and to evaluate the clinical performance of denture bases fabricated from each technique. Twenty completely edentulous participants received both conventional impressions and d...
M. Habash, Ammar Almustafa, Hasan Alzoubi· Scientific Reports· 0 citations
BackgroundThe accuracy of marginal and internal adaptation is an important determinant of the biological, mechanical, and clinical performance of indirect dental restorations. Zirconia crowns are increasingly fabricated using computer-aided design and computer-aided manufacturing (CAD/CAM). Conventional subtractive mil...
Vritti Aggarwal, Manjinder Singh, Amanat Kaur Randhawa et al.· Adolescência e Saúde· 0 citations
Background: Provisional restorations play an important role in fixed prosthodontics in maintaining function, esthetics and protecting prepared teeth until permanent restorations are applied. Digital dentistry is becoming more and more common, and computer-aided design/computer-aided manufacturing (CAD-CAM) milling and...
K. N. Chowdary, Muvva Suresh, D. Babu et al.· International Journal of Dru...· 0 citations