Accurate quantitative analysis of homogeneous bulk samples is critical in materials science and mineral industry applications, yet conventional standards-based Energy Dispersive Spectroscopy (EDS) quantitative analysis remains reliable and widely used. However, for some laboratories or sample types, obtaining, maintaining, or matching appropriate physical standards may be inconvenient or impractical. In this study, we introduce a dynamic framework for elemental quantification of homogeneous multi-element bulk samples investigated in an SEM at an accelerating voltage of 20 kV by integrating Monte Carlo X-ray (MC X-ray), a Monte Carlo simulation program, with artificial neural networks (ANNs). Synthetic spectra and corresponding weight fraction pairs were generated using MC X-ray under the same 20 kV measurement condition, and a multilayer perceptron (MLP) was trained to map spectral features to elemental weight fractions. Validation across 11 certified standard samples yielded root mean square error (RMSE) values from 0.0056 to 0.0179 in weight fraction and coefficients of determination (R2) from 0.9873 to 0.9981, even in cases with overlapping peaks. For elements with certified weight fractions of at least 0.05, the mean absolute percentage error was 4.41%. The model, tailored to specific sample and measurement conditions, enables quantitative analysis in under 15 min on consumer-grade hardware. By reducing the dependence on physical standards and calibration procedures, this approach provides a complementary simulation-based method for quantitative microanalysis when suitable measured standards or stored standard libraries are not readily available for the analysis of homogeneous bulk materials.
Evaluating the energy transmission ratio of an X-ray beam through a polymer composite is a challenging task in radiation shielding studies. The reference solution with Monte Carlo transport simulation is highly accurate but computationally expensive: each of our reference simulations is capped at $4\times10^9$ photon h...
ABSTRACT This work evaluates micro- and nano-sized bismuth oxide fillers in poly(methyl methacrylate) (PMMA) composites for low-energy X-ray shielding. Eleven material formulations were examined: neat PMMA and PMMA/Bi2O3 composites containing 10, 20, 30, 40, or 50 wt% filler in either micro- or nano-sized form. Seven p...
Abstract Purpose To obtain better elemental compositions (ECs), physical densities (PDs), and relative linear stopping powers (RLSPs) of tissues scanned by single or dual energy computed tomography for use by Monte Carlo (MC) simulations of light ion beam therapy. Methods and materials The RLSPs of 12 animal tissue sam...
Xiao-Li Liu, M. Moyers· Journal of Applied Clinical...· 0 citations
Objective. While the process of designing a low-to-medium energy transmission x-ray target follows a similar general approach throughout the literature, the specific methodology can vary substantially. The goal of this study was to determine the sensitivity of x-ray target optimization to different methods of x-ray qua...
B. Insley, Mohammad R. Salehpour, D. Bartkoski· Physics in Medicine and Biol...· 0 citations
This study presents the measured X-ray fluence spectra emitted by 15 diagnostic and interventional radiology X-ray imaging devices. The results, comprising more than 180 different spectra, may be used as a compendium and as a basis for further studies in medical X-ray applications. The measurements were conducted using...
J. Šolc, Markus Borowski, Vittorio Cannatà et al.· Journal of Instrumentation· 0 citations