Static strength and eight-mode transient screening of a stiffened Q235A steel enclosure under internal pressure

Sep 2026 · Journal of Physics, Conference Series · Vol 3325 · 0 citations · 9 references
Physics

Abstract

A stiffened Q235A steel enclosure for a coal-mine power monitoring substation is assessed against an adopted differential proof pressure of 1.11 MPa. Manufacturer documents specify a 404 mm x 306 mm x 61 mm enclosure, an approximately 42 kg shell, and an approximately 50 kg complete product. The STEP geometry confirms a 20 mm base but omits the cover. A nominal 14 mm Q235A equivalent cover is therefore introduced as an explicit engineering assumption, based on a 12.6 mm mass-equivalent full plate and a conservative plate-thickness screen; its modal mass is calibrated to retain the 42 kg shell mass. The original 4 mm strong-flange model gives 144.670 MPa and 0.102990 mm. The lug-only B3 case gives 621.03 MPa and is retained as a failure-warning case rather than discarded. The supplemental B4 model, with lug support and a bonded cover, gives 89.747 MPa and 0.119070 mm; inclusion of the complete 50 kg product weight changes the worst stress to 89.765 MPa. The first eight B4 frequencies are 414.88 - 2438.80 Hz. An eight-mode transient reconstruction, using a published pressure-piling rise time of 1.51 ms scaled to 1.11 MPa, gives peak stresses of 91.279 MPa and 94.114 MPa for half-sine and triangular pulses at 2% damping. These results are screening bounds and do not replace measured pressure histories, bolt-contact/preload analysis, or prototype testing.