Design for Symmetrical Loading Conditions During Accelerated Lifetime Tests of Aluminum Electrolytic Capacitors for DC-Link Applications
Abstract
This paper addresses the challenge of ensuring uniform AC and DC loads on individual electrolytic capacitors during accelerated aging tests, despite inherent initial variations in electrical parameters and anticipated drift due to degradation. The primary issue arises from the dynamic impedance changes of the capacitors, which would lead to inconsistent ripple current and thus uneven loading under a fixed AC ripple voltage. Addressing these challenges with conventional methods often involves significant cost, either through more complex and expensive test setups or by accepting less reliable data. Ensuring symmetrical ripple current distribution, despite varying capacitor impedances, necessitates active adjustment of the AC ripple voltage. The proposed analog control loop adjusts ripple current to ensure symmetrical loading across all capacitors under test, which is essential for generating reliable lifetime data. The concept for the analog regulation is validated using simulations, where the capacitor-specific values are varied to represent natural manufacturing tolerances as well as degradation effects.