Skip to content
Open access

Evaluation of Tendon Fastener Designed for Percutaneous Placement in an Ovine Model for Repair of Articular-Sided Rotator Cuff Tears

Oct 2026 · Journal of Functional Biomaterials · Vol 17, pp. 526 · 0 citations · 33 references
Medicine

TL;DR

The fastener offers similar biomechanical stability to that of a screw-and-washer construct in the treatment of partial rotator cuff tears in an ovine model and demonstrates comparable histology across the graded parameters regardless of the evaluated animal or sample.

Abstract

Introduction: Surgical treatment for partial-thickness rotator cuff tendon (RCT) tears often involves open or arthroscopic conversion to a full-thickness tear. A novel method has been developed that utilizes sutureless bone-to-tendon fixation using a percutaneous fastener. Purpose: This study characterizes the biomechanical stability of the fastener in a partial-tear ovine rotator cuff model compared to that of a screw-and-washer. Methods: The study included an ex vivo cadaveric phase and an in vivo pilot. During the ex vivo phase, the infraspinatus tendon was partially transected in 20 cadaveric sheep shoulders. Shoulders were allocated into three groups: fastener (FS) (n = 10), screw-and-washer (S/W) (n = 7), and an empty group without fixation (n = 3). In an in vivo pilot, three sheep underwent bilateral partial infraspinatus transection and repair, with the fastener in one shoulder and the screw-and-washer in the contralateral shoulder; animals were euthanized at 8 weeks for histological analysis. Both cohorts underwent biomechanical assessments, and the in vivo samples underwent histological dissection and analysis. Results: No significant biomechanical differences were noted among the three groups in ultimate load (FS: 2822 N, S/W: 2599 N, empty: 2924 N), ultimate displacement (FS: 15.9 mm, S/W: 15.5 mm, empty: 13.8 mm), stiffness (FS: 252.4 N/mm, S/W: 237.7 N/mm, empty: 279.9 N/mm), cross-sectional area (FS: 90.0 mm2, S/W: 93.0 mm2, empty: 78.8 mm2), ultimate stress (FS: 32.9 MPa, S/W: 28.3 MPa, empty: 37.8 MPa), ultimate strain (FS: 0.203 mm/mm, S/W: 0.183 mm/mm, empty: 0.183 mm/mm), or elastic modulus (FS: 231.1 MPa, S/W: 220.3 MPa, empty: 271.3 MPa). The mode of failure was most frequently a mid-substance tear. Both the fastener and the screw-and-washer demonstrated comparable histology across the graded parameters regardless of the evaluated animal or sample. Conclusions: The fastener offers similar biomechanical stability to that of a screw-and-washer construct in the treatment of partial rotator cuff tears in an ovine model. Clinical Relevance: The results of this animal model study provide evidence to consider further clinical testing.

Read PDF

Similar papers

Open access Sep 2026

Cable Reinforcement Combined With Biologic Tuberoplasty Restores Muscle Forces and Scapular Strain in an Irreparable Rotator Cuff Tear Model: A Cadaveric Study.

PURPOSE To investigate the biomechanical impact of an irreparable rotator cuff tear and compare the isolated and combined effects of rotator cable reconstruction (CR) and biologic tuberoplasty (BioTB). METHODS Eight cadaveric shoulders were tested using an ex vivo dynamic shoulder simulator in forward flexion (FF) an...

Mohammad M. Haddara, Natalie Guggenbach, Kevin Sun et al. · 0 citations
Open access Oct 2026

pADM patch augmentation for rotator cuff repair: In vivo safety and efficacy in a canine model

The pADM patch exhibits favorable biosafety and biocompatibility, promotes tendon structure recovery and tendon-bone healing, and enhances biomechanical strength, with promising potential for clinical translation.

Jian-Bo Li, Qing-Jun Kong, Qian Xu et al. · 0 citations
Open access Oct 2026

Comparison of an anchor plate with suture anchor and transosseous constructs for rotator cuff repair in a polyurethane foam block: a biomechanical study

Rotator cuff repair can be difficult in patients with poor bone quality, as fixation may fail before proper tendon healing occurs. Common repair methods, such as suture anchors and transosseous sutures, are especially vulnerable to anchor pull-out or bone cut-through in osteoporotic bone. To address this limitati...

A. Amini, A. Nourani, Parviz Ahangar et al. · 0 citations
Open access Sep 2026

Isotension Versus Low-Tension Fixation in Arthroscopic Biceps Tenodesis: A Comparative Study of Clinical Outcomes.

BACKGROUND It remains uncertain whether anatomic or reduced tension provides superior clinical outcomes in tendon-to-bone fixation for long head of the biceps tendon (LHBT) tenodesis. HYPOTHESIS/PURPOSE The purpose was to compare clinical outcomes between isotension and low-tension fixation techniques for LHBT tenode...

Jin-Ming Zhang, Chuan-Hai Zhou, Shao-Yun Hao et al. · 0 citations
Open access Nov 2026

High‐Strength Tape for Cable Structure Reconstruction During Arthroscopic Repair of L‐Shaped Rotator Cuff Tears

Abstract With the innovation and progressive maturation of arthroscopic techniques, the advantages of minimally invasive surgery and accelerated rehabilitation have made arthroscopy a preferred option for patients with rotator cuff injuries. However, for complex rotator cuff tears, such as “L‐shaped” tendon tears, the...

Shun-Nan Liu, Yi-Zhong Ren, Yan-Bo Jia et al. · 0 citations
Open access Sep 2026

Biomechanical comparison of innovative suture techniques for repair of Achilles tendon rupture in a porcine flexor tendon model

In recent years, evidence-based progressive rehabilitation protocols following the surgical treatment of Achilles tendon rupture have been shown to be safe and appear superior to more restrictive treatment regimens. These protocols mainly rely on early mobilization and weight bearing. To enable this during postoperativ...

Lasse Weigand, Benjamin Liebrand, Sophia Scheible et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.