Nov 2026· Scientific Reports· Vol 16· 0 citations· 27 references
Abstract
This paper investigates the fault-tolerant (FT) operation of the T-type converter using a cascaded H-bridge (T2C-HB) topology under open-circuit failures (OCF) occurring in any IGBT switch. The high number of switches in the hybrid multilevel converter (HMC) increases the possibility of switch faults. However, existing FT control methods for HMC primarily focus on local faults, making them ineffective in addressing global faults and thereby limiting overall system reliability. To achieve global FT control, this paper proposes an FT strategy based on model predictive control (FT-MPC), which consists of two stages. In the first stage, the optimal redundant voltage vector position is determined by employing an optimal current tracking strategy. In the second stage, an initialization function is introduced to integrate various types of OCF into a unified framework. By employing weighting factors within the selected redundant voltage vectors, the optimal switching states are determined. The proposed method effectively handles various types of OCF and is applicable to any HMC incorporating cascaded H-bridge modules. Simulation and experimental results validate the feasibility and effectiveness of the proposed method.
Reliable fault-tolerant operation is essential to single-phase-input three-phase-output converter-fed induction motor drive systems in some special applications. In this article, we present a reconfigurable fault-tolerant control scheme for such motor drive systems. As the studied fault-tolerant strategy and the normal...
This paper presents an enhanced fault diagnosis method for identifying open-circuit faults in the switches of Three-Level Neutral Point Clamped (NPC) inverters integrated into Static Synchronous Series Compensator (SSSC) systems. Although previous studies have mainly focused on open switch faults in two-level convert...
Laiche Zeghdi, Mohamed Naoui, M. L. Bendaas et al.· Scientific Reports· 0 citations
Cascaded energy storage systems are well-suited for medium- and low-voltage power grids, offering an effective solution to power quality issues caused by the integration of renewable energy sources. However, the reliability of cascaded H-bridge converters is critically challenged by the pervasive integration of power s...
Yang Zhang, Yi-Hang Liu, Liu-Qi Zhan et al.· International Conference on...· 0 citations
The growing demand for sustainable high-power electric drive systems requires advanced control strategies capable of ensuring high efficiency, operational reliability, and continuous service under fault conditions. Parallel multilevel inverter-fed dual-star induction machine (DSIM) drives have emerged as a promising so...
Elyazid Zaidi, Habib Benbouhenni, A. Mabrek et al.· Energies· 0 citations
Multilevel converter topologies are used in diverse applications requiring medium-voltage and high-power ratings, such as motor drives, power quality compensators, distributed generation, solid-state transformers, and energy storage systems. This paper presents a comprehensive literature review on fault diagnosis, faul...
M. Gonzalez-Garcia, Victor M. Cárdenas, R. Álvarez-Salas et al.· Applied Sciences· 0 citations
This paper presents a novel fault-tolerant model predictive control (FTMPC) framework for fuel cell hybrid electric vehicles (FCHEVs) used for postal delivery applications. The main contribution of the proposed FTMPC is the adaptive adjustment of the model predictive control cost function weights based on fault severit...
Akram Nedjaoui, S. Bououden, M. Chadli et al.· Processes· 0 citations