RePrior is introduced, a multi-stage progressive prior-correction framework that addresses correction actionability, measurement feasibility, and representation expressivity, and delivers additional gains in volumetric quality and observed-view projection fidelity, with consistent gains in held-out-view fidelity in the backbone-matched evaluation.
Abstract
Sparse-view cone-beam computed tomography (CBCT) is severely under-constrained by limited X-ray projections. Learned reconstruction can provide complementary anatomical information, but using it as a prior in patient-specific Gaussian reconstruction introduces two challenges. First, the discrepancy between the learned prior and current reconstruction is spatially non-uniform: some local differences contain useful missing 3D information, whereas others reflect prior bias. Second, even a volumetrically beneficial correction can conflict with the observed X-ray measurements. Since X-ray measurements are line integrals, spatially separated corrections may affect overlapping rays, with their signed projection responses reinforcing or partially canceling in the measurement residual, so their feasibility cannot always be assessed independently. In this paper, we introduce RePrior, a multi-stage progressive prior-correction framework that addresses correction actionability, measurement feasibility, and representation expressivity. Selective Correction Proposal (SCP) first identifies actionable signed local corrections from prior--reconstruction discrepancies. Measurement-Constrained Reconciliation (MCR) then jointly enforces their consistency with patient-specific X-ray measurements, while Hybrid Residual Enhancement (HRE) recovers additional correction capacity through complementary voxel- and Gaussian-domain degrees of freedom around the reconciled anchor. RePrior requires neither test-time ground truth nor case-specific network fine-tuning. RePrior gains approximately 2.6~dB in 3D PSNR over R$^2$-Gaussian across LUNA16, PANORAMA, and PENGWIN. Beyond prior-assisted reconstruction, it delivers additional gains in volumetric quality and observed-view projection fidelity, with consistent gains in held-out-view fidelity in the backbone-matched evaluation.
The results indicate that jointly enforcing projection-domain completion, analytic imaging geometry, and image-domain refinement is an effective strategy for limited-angle CBCT reconstruction.
Ming-Zhe Hu, Shao-Yan Pan, Yuan Gao et al.· Physics in Medicine and Biol...· 0 citations
Ultra-sparse cone-beam computed tomography (CBCT) reconstruction is important for low-dose and rapid 3D imaging, including C-arm-assisted interventions, yet the Feldkamp-Davis-Kress (FDK) algorithm and simultaneous iterative reconstruction technique (SIRT) degrade under sparse views. We propose a cross-domain framewo...
Bo-Dong Bi, Bo Yang, Zhi-Xin Liu et al.· Measurement and control (Lon...· 0 citations
Sparse-view cone-beam computed tomography is widely used for fast, low-dose volumetric imaging and lesion localization in dentistry and image-guided interventions, but it introduces severe artifacts. Feed-forward Gaussian methods transfer the reconstruction cost to training and decode each coordinate from projection-al...
Zi-Han Deng, Zhen-Zhen Gong, Yu-Jie Liu et al.· 0 citations
Objective. The primary objective of this research is to address the challenges of limited-angle computed tomography (CT) reconstruction, which arises when projection data is acquired over an angular range smaller than required for theoretically exact reconstruction. This ill-posed problem leads to serious artifacts tha...
Gen-Wei Ma, Di-Meng Xia, Yu-Tong He et al.· Physics in Medicine and Biol...· 0 citations
As computed tomography (CT) applications have expanded, scenarios with restricted angular coverage, known as limited-angle tomography (LAT), are increasingly encountered. LAT commonly arises in industrial and non-destructive testing applications, where CT cannot fully traverse an object due to its size or due to obst...
Seokwon Oh, Seung-Min Yoo, Jun-Ho Lee et al.· Scientific Reports· 0 citations
A shape-guided Gaussian splatting framework for sparse-view X-ray 3D reconstructions that ensures anatomically consistent reconstruction and improves PSNR by 2.83 dB over a state-of-the-art Gaussian splatting baseline with as few as 5 views is proposed.
Pranav Poudel, Florence Dell'Aniello Picard, N. Shehata et al.· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.