Skip to content
Open access

Adaptive Closed-Loop Cathodic Protection of Concrete-Coated Steel Pipelines under Progressive Marine Flow-Induced Coating Degradation

Sep 2026 · Sri Lanka Journal of Aquatic Sciences · Vol 31, pp. 79-91 · 0 citations

Abstract

Concrete-coated steel pipelines are widely used in offshore and coastal marine infrastructure, including risers, jetties, piles, and platform legs. Such structures face progressive corrosion as concrete coatings degrade under flowing seawater, wave impact, and chloride ingress. This study investigated the real-time adaptive capability of a closed-loop Impressed Current Cathodic Protection (ICCP) system responding to dynamic, flow-induced coating degradation, a scenario more realistic than conventional static-defect studies. Intact 5 mm and 10 mm concrete coatings on wire beam electrode (WBE) steel specimens were subjected to sequential pressure testing at 1, 2, 4, and 6 bar in a recirculating flow loop rig, in tap water, 3.5% NaCl solution, and natural seawater, while the ICCP system continuously monitored electrochemical conditions and adjusted protective current. ANSYS Discovery CFD analysis confirmed that laboratory surface velocities (0.62–1.58 m/s) accurately replicated marine splash zone conditions. Settling current (the peak protective current applied immediately after protection was initiated or coating conditions changed) ranged from 0.012 mA for a deliberate hairline crack to 0.810 mA under 6.5-hour extended NaCl exposure with intact overall coating, a 179% increase over standard-duration testing that indicated real-time recognition of progressive erosion. Post-test inspection confirmed a progression from an intact coating through crevice formation and partial disbondment to complete failure at 4 bar. Across all 19 test conditions, the closed-loop system attained and maintained protective conditions in every case, with no sustained under-protection, while autonomously managing a 67-fold variation in current demand.  This performance was achieved within the tested conditions and durations only and should not be interpreted as evidence of long-term operational reliability.  Results indicate that smart closed-loop ICCP offers: (i) fast, adaptive protection under flow-induced damage; (ii) current-adjustment behaviour consistent with hydrogen embrittlement avoidance; and (iii) greater responsiveness than conventional static ICCP in dynamic marine environments. The findings are also discussed in the context of the potential environmental pressure of cathodic protection systems, including chlorine production and metal release, and their relevance to marine ecosystem health and coastal water quality.

Read PDF

Similar papers

Review Open access Oct 2026

Mechanical And Materials Aspects Of Corrosion Protection And Rehabilitation In Buried Pipelines: A Structured Review

Buried metallic pipelines lose structural integrity through soil-induced corrosion and interacting mechanical, microbial, and electrochemical processes. This structured narrative review synthesises studies, engineering standards, and reference works on degradation mechanisms, protective coatings, cathodic protection, c...

F. T. Al-Maliky, Sarah Abdul Kadhim, Aseel Al-Khatat · 0 citations
Open access Sep 2026

Mitigating flow-assisted corrosion of carbon steel through chemical-mechanical surface engineering

Flow-assisted corrosion severely limits the lifetime of carbon steel infrastructure in energy systems, yet the role of surface nano-engineering under turbulent conditions remains insufficiently understood. Here, we demonstrate that chemical-mechanical polishing (CMP) can be repurposed as a corrosion-mitigating surface-...

Mohamed Salih Ahmed, Buthainah Ali Al-Timimi, A. Al-Dulaimy et al. · 0 citations
Oct 2026

Failure Analysis of Steel Wire‐Reinforced Composite Pipes for Gas Field Flowback Fluid

To clarify the failure mechanism of steel wire‐reinforced thermoplastic (SWRTP) pipes in flowback fluid pipelines, failed and intact samples were systematically investigated. Compression cracking and hydraulic burst tests confirmed the original intact pipe met standard requirements. The failed pipe exhibited circum...

Han Ding, Hou-Bu Li, Guo-Quan Qi et al. · 0 citations
Open access Oct 2026

CORROSION BEHAVIOUR OF REINFORCED CONCRETE IN LAGOS LAGOON: INFLUENCE OF WATER-CEMENT RATIO AND COVER DEPTH UNDER PHOTOVOLTAIC-ASSISTED IMPRESSED CURRENT TESTING

Globally, reinforced concrete (RC) structures exposed to marine environments are highly prone to corrosion due to chloride penetration - which deteriorates steel reinforcement, concrete and their bond, reduces service life and increases maintenance costs. This study examined the corrosion behavior of RC specimens expos...

Douglas E. Osegbowa, Umukoro Ogheneale Orie, Roland Ogirigbo Okiemute · 0 citations
Open access 2026

Corrosion Analysis of Offshore Oil and Gas Pipelines in Africa: Nonlinear Finite Element Assessment of Burst Pressure

Corrosion-induced metal loss reduces the burst capacity of ageing offshore pipelines, yet its effect on pipelines in African offshore fields remains poorly quantified. This study presents a nonlinear finite element analysis (FEA) of an API 5L X70 steel pipeline (outside diameter 600 mm, wall thickness 30 mm) containing...

Adewunmi Odedina, M. Inegiyemiema, King Nyeche Wugha · 0 citations
Open access Nov 2026

Pore structure evolution and chloride ion permeability of concrete under sulfuric acid

Underground reinforced concrete pipelines experience structural degradation due to external high-frequency fatigue loads and internal corrosive environments. This study investigates the effects of prolonged sulfuric acid attack on concrete specimens, focusing on mass loss, volume loss, surface roughness, corrosion dept...

Hui-Fang Liu, Lin-Bing Wang · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.