Both lenses offer good visual quality and increased spectacle independence, with a similar overall side-effect profile, and the AT LISA tri 839MP provides superior intermediate vision and related patient satisfaction, with a similar overall side-effect profile.
Abstract
Purpose To comparatively analyze visual quality after cataract surgery with implantation of the extended depth of focus (EDOF) refractive-diffractive hybrid bifocal intraocular lens (IOL) AM3UH and the refractive-diffractive hybrid trifocal intraocular lens AT LISA tri 839MP. Methods This was a multicenter, retrospective and prospective bidirectional cohort study. Sixty-nine patients (69 eyes) with AM3UH IOL implantation were enrolled in the AM3UH group. Sixty-two patients (62 eyes) implanted with AT LISA tri 839MP IOL were enrolled in the 839MP group. Uncorrected distance visual acuity (UDVA, logMAR), uncorrected intermediate visual acuity (UIVA, logMAR), uncorrected near visual acuity (UNVA, logMAR) and best corrected distance visual acuity (BCDVA) were assessed before and 3 months after surgery. The visual function index 11R (VF-11R) was used to evaluate the quality of life after cataract surgery. Light interference, spectacle independence and postoperative satisfaction were evaluated by questionnaires. Results The preoperative UDVA of AM3UH group and 839MP group was (0.93 ± 0.38) logMAR and (0.90 ± 0.47) logMAR, respectively. At 3 months postoperatively, the UDVA, UIVA, UNVA and BCDVA of the AM3UH group were (0.14 ± 0.19) logMAR, (0.13 ± 0.12) logMAR, (0.15 ± 0.1) logMAR, and (0.09 ± 0.11) logMAR, respectively; and those of the 839MP group were (0.90 ± 0.47) logMAR, (0.12 ± 0.08) logMAR, (0.07 ± 0.08) logMAR, (0.12 ± 0.06) logMAR, and (0.05 ± 0.04) logMAR, respectively. Both IOLs (AM3UH and 839MP) significantly improved postoperative UDVA. No significant differences were observed between groups regarding distance, near, or best-corrected distance visual acuity (P > 0.05); however, the trifocal 839MP group demonstrated significantly superior UIVA. Patient satisfaction with intermediate and near vision was also higher in the 839MP group, though far vision satisfaction was similar. Both lenses showed low and comparable levels of glare and halos (the majority of patients were either asymptomatic or reported only mild symptoms), with a slight trend toward less glare and more halos in the 839MP group. Rates of spectacle independence at all distances did not differ significantly (P > 0.05). Conclusion Both lenses offer good visual quality and increased spectacle independence. The AT LISA tri 839MP provides superior intermediate vision and related patient satisfaction, with a similar overall side-effect profile.
PURPOSE
To evaluate visual and refractive outcomes, visual quality, patient satisfaction, and spectacle independence after bilateral implantation of a diffractive trifocal intraocular lens (IOL).
METHODS
Thirty-three patients (66 eyes) underwent refractive lens exchange (54.5%) or cataract surgery (45.5%). Exclusion...
Alaa M. Eldanasoury, Karim Ayesh, Z. Zidan· Journal of refractive surger...· 0 citations
The FineVision HP IOL demonstrated favorable short-term refractive accuracy and visual performance in this prospective cohort, although larger comparative studies with longer follow-up are warranted.
Camille Bosc, Eloïse Le Malefan, Pauline Boury et al.· Clinical Ophthalmology· 0 citations
Purpose To evaluate the effectiveness and safety of a new trifocal intraocular lens (IOL) in patients with age‐related cataracts 12 months after surgery. Methods This prospective, noncomparative, multicenter study included 122 patients (244 eyes) undergoing cataract surgery with bilateral implantation of the AT ELANA 8...
P. Mojžiš, Andrea Janeková, L. Hrčková et al.· Journal of Ophthalmology· 0 citations
PURPOSE
To compare visual performance, low-contrast visual acuity, stereopsis, and patient-reported outcomes of a refractive Extended Depth of Field (EDF) intraocular lens (IOL) implanted targeting mini-monovision or emmetropia target.
DESIGN
Prospective, randomized, controlled, patient- and examiner-masked single-ce...
Johannes Zeilinger, M. Ruiss, C. Pilwachs et al.· American journal of ophthalm...· 0 citations
PURPOSE
To evaluate the visual performance of an enhanced monofocal intraocular lens (IOL) and the influence of pupil size.
METHODS
This prospective, observational, single-center study was conducted at Hospital Clínico San Carlos (Madrid, Spain). Patients undergoing cataract surgery with an enhanced monofocal IOL (en...
N. Garzón, P. Arriola-Villalobos, Natalia Hormigo-Márquez et al.· Journal of refractive surger...· 0 citations
Aim: to evaluate visual acuity, contrast sensitivity, and mesopic vision following implantation of the fully refractive extended depth-of-focus (EDOF) intraocular lens (IOL) TECNIS PureSee in patients with cataract and stage I–II primary open-angle glaucoma (POAG).
Patients and Methods: the study included 24 patients (...
O. Gorynina, R. Fayzrakhmanov, O. Pavlovskiy· Russian Journal of Clinical...· 0 citations