Analysis of Electrical Parameter Variations in MMC Submodules Under IGBT Open-Circuit Fault Conditions
Abstract
Modular multilevel converters (MMCs) have become the core topology of next-generation flexible direct current (DC) transmission systems owing to their salient technical advantages. However, as the total number of series-connected submodules within converter valves continuously expands, the probability of open-circuit faults in IGBTs has climbed significantly, severely jeopardizing the safe and sustainable operation of the system. To address the issue that existing research predominantly focuses on the development of fault diagnosis algorithms while lacking quantitative comparisons of IGBTs device electromagnetic transient mechanisms, a detailed MMC inverter model is constructed on the Simulink platform. The dynamic response trajectories of the capacitor voltage, arm current, and device current following open-circuit faults in the upper and lower IGBTs within the same submodule are comprehensively compared and analyzed. Simulation results demonstrate that an upper IGBT open-circuit fault induces a high-level deadlock of the capacitor voltage, indicating a strong self-healing capability of the system. Conversely, a lower IGBT open-circuit fault triggers a continuous overcharging, which forces a reduction in the arm current amplitude and causes severe distortion. This study provides a solid theoretical foundation for converter valve condition monitoring and fault diagnosis.