Oct 2026· Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji· 0 citations· 21 references
Abstract
The increasing penetration of distributed photovoltaic (PV) generation in distribution networks poses significant challenges to voltage regulation, particularly during periods of high irradiance and low demand. Inverter Tripping and Dynamic Active Power Control (DAPC) have been common solutions to systems that lack an extensive communication infrastructure, where voltage control must rely on decentralized or limited-communication strategies. While these methods are effective in preventing overvoltage, they often result in excessive active power curtailment and inefficient use of PV power. This paper investigates the coordinated integration of tap-changing low-voltage regulators (LVRs) with inverter-based active power control under a limited-communication framework. By prioritizing feeder-level voltage regulation through LVR tap adjustments and employing active power control methods only when necessary, the proposed approach reduces the reliance on aggressive curtailment while maintaining voltage within acceptable limits. The proposed strategies are tested on a modified IEEE 33-bus distribution system under high PV penetration using time-series simulations. The results demonstrate that the coordinated double-LVR and DAPC scheme reduces PV curtailment by 46.036% and 29.631%, respectively, and improves the voltage standard deviation by 5.2109% and 3.8115%, respectively, compared to tripping the inverter and DAPC, respectively, while achieving improved voltage regulation across the feeder. These findings indicate that limited-communication multi-device coordination provides an effective solution for PV-rich distribution networks.
The exponential integration of distributed energy resources (DERs), particularly solar photovoltaic (PV) systems, into low-voltage (LV) distribution networks has introduced critical challenges regarding voltage stability. In high-impedance feeders with low $X / R$ ratios, excessive PV generation during light-load perio...
Piyusha Kukade, Prashant Surana, Amit Kumar et al.· 2026 Energy Conversion Congr...· 0 citations
Under high-penetration photovoltaic integration, node voltage over-limits are frequently experienced by active distribution networks during light-load periods at noon due to reverse active power flow, while voltage sag risks are faced during nighttime or sudden drops in photovoltaic output. As a result, voltage fluctua...
The rapid increase of photovoltaic generation in low-voltage distribution networks can trigger voltage rise and overvoltage, particularly on feeders with a high resistance-to-reactance ratio. This study compares two smart-inverter voltage regulation strategies—volt–var control and power-factor control—to mitigate overv...
Introduction. The integration of photovoltaic (PV) systems into the conventional power system is one of the most promising approaches for efficiently meeting increasing energy demand. Problem. The increasing installation of PV systems makes significant challenges for voltage regulation due to non-continuous generation...
O. A. Hussein, A. N. Alsammak· Electrical Engineering &...· 0 citations
High penetration of photovoltaic (PV) generation reduces system strength and introduces voltage control, power quality, and transfer capacity constraints across transmission and distribution networks. This review comparatively examines the operating principles, control mechanisms, dynamic response, and deployment impli...
Leeshen Pather, Rudiren Sarma· WSEAS Transactions on power...· 0 citations