To address the difficulty in accurately evaluating the vertical bearing behavior of prestressed high-strength concrete (PHC) pipe pile-group foundations, this study investigated three single piles and an eight-pile group with a Wang-shaped irregular pile cap through field static loading tests and theoretical analysis. The measured ultimate bearing capacities of single piles D1/D2 and D3 were 7040 and 3000 kN, respectively. For the pile-group foundation, the ultimate bearing state was not reached under the maximum applied load of 15,000 kN, at which the settlement was only 3.52 mm. The pile-head load distribution followed the order corner piles > side piles > inner piles, with corresponding load proportions of approximately 13.9%, 12.9%, and 9.4%. The calibrated API and hyperbolic models predicted the single-pile bearing capacities with errors ranging from 0.23% to 3.40%. The API model better represented the steep-drop portion of the Q-s curve, whereas the hyperbolic model more accurately predicted the initial stiffness and low-load response. For pile-group foundations, the combined equivalent-pier and load-transfer method showed good applicability. The main contribution of this study is to provide field evidence for the vertical bearing and load-transfer behavior of a large-diameter PHC pipe pile group with a Wang-shaped irregular pile cap, extending existing studies that have mainly focused on single piles or conventional symmetric pile groups. The results also provide a quantitative basis for the analysis and design of PHC pipe pile-group foundations in highway bridge engineering.
To investigate the vertical bearing performance of single and group piles in layered saline soil, a series of indoor model tests were conducted. A multi-pile theoretical calculation model correlating soil salinity, pile–soil shear stiffness, and vertical bearing capacity was established, and corresponding calculation m...
The use of foundation systems on clayey soils poses serious challenges due to their low shear strength and high compressibility, making the need for appropriate sustainable foundation systems necessary. This study analyzed the structural capacity and the material effectiveness of reinforced concrete piled raft and pile...
A. L. Hayal, A'Amal A. H. Al-Saidi· Journal of Building Material...· 0 citations
To tackle the problem of poor construction quality of pile foundations in karst areas for transportation projects, a specialshaped bored pile known as the bag-sealed pile was examined in this paper. Featuring its unique branched structures for cavity filling, the pile was designed to improve the reliability of pile f...
Zhi-Yu Lu, Jue-Wen Zhu, Fu-You Zhang et al.· Journal of the Geological So...· 0 citations
The hybrid caisson–steel tubular pile group anchorage (CSTPGA) provides an optimized anchorage foundation solution for long-span suspension bridges. In this study, three-dimensional finite element analyses were carried out to investigate the performance of the CSTPGA under the main cable tension. The numerical modeling...