Jul 2026· Journal of Applied Clinical Medical Physics· Vol 27· 0 citations· 13 references
Medicine
TL;DR
The high‐density bolus demonstrated satisfying dosimetric reliability, particularly when modeled with the Acuros XB algorithm, and addressed the build‐up challenge inherent to MV photons, even in the presence of small air gaps, without increased toxicity in a large cohort of patients.
Abstract
Abstract Background Accurate dose deposition in superficial radiotherapy remains challenging due to the inherent skin‐sparing effect of megavoltage photon beams and difficulties in ensuring bolus conformity. Purpose This study aims to comprehensively evaluate the dosimetric characteristics of the room‐temperature‐malleable high‐density bolus, to evaluate the accuracy of dose calculation and to assess clinical outcomes in a clinical cohort of 55 patients. Materials and Methods The dosimetric validation was performed through the use of dose measurements in a solid water phantom on top of which a 1.0 cm thick high‐densitybolus was positioned. Absolute depth dose measurements beyond the bolus were obtained by combining an absolute point dose (ion chamber) measurement at 1.0 cm depth beyond the bolus with relative depth dose measurements by using a microDiamond detector. Measurements were performed using 6 megavoltage (MV) flattening‐filter‐free (FFF) photon beams on an Halcyon and on a TrueBeam treatment unit. Obtained data were compared to dose calculations with both photon dose calculations available in the Eclipse treatment planning system (TPS): Analytical Anisotropic Algorithm (AAA) and Acuros XB (AXB). The impact of non‐conforming interfaces was assessed by introducing 0.5 to 2.0 cm thick air cavities between bolus and skin. Skin dose loss due to the air cavities was measured for static open fields and for dynamic sweeping gap fields. Clinical outcomes of 55 patients treated between October 2023 and March 2025 were retrospectively analyzed. Results Depth dose measurements confirm that a 1.0 cm high‐density bolus was sufficient to effectively overcome the build‐up region of the 6FFF photon beam. The AXB dose calculation algorithm provided the best agreement between measurements and calculations. Air gaps between the bolus and the skin resulted in clinically relevant skin dose reductions, ranging from approximately 1% to 20%, depending on field size and gap thickness, especially for clinical target volumes < 5.0 cm, large (> 1.0 cm) air gaps, or the use of large static fields. Among the 55 included patients, acute dermatitis toxicity was predominantly Grade 1 (49%) or Grade 2 (47.0%), with a low incidence of severe adverse events (Grade III: 4 %, Grade IV: 0%). Conclusion The high‐density bolus demonstrated satisfying dosimetric reliability, particularly when modeled with the Acuros XB algorithm. The bolus addressed the build‐up challenge inherent to MV photons, even in the presence of small air gaps, without increased toxicity in a large cohort of patients. This strategy represents a viable and accessible solution for ensuring accurate and conformal dose delivery in superficial tumors.
Each year, the incidence of skin cancer continues to rise worldwide. Radiotherapy remains a well-established treatment option; however, its effectiveness can be limited by technical constraints. In clinical practice, a water-equivalent material known as a bolus is often placed over the tumor site to restore electronic...
G. Tosetti, J. Fontbonne, D. Lebhertz et al.· Journal of Physics, Conferen...· 0 citations
BACKGROUND
High-dose-rate (HDR) brachytherapy is a widely used treatment modality for breast cancer, providing highly localized radiation delivery with improved normal tissue sparing. The choice of radionuclide source plays an important role in determining dosimetric characteristics and the available evidence for clini...
A retrospective dosimetric analysis was conducted using treatment planning systems from two radiotherapy centers in Cross River State, Nigeria, equipped with advanced linear accelerators delivering Intensity-Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT), to investigate the levels of out...
B. Archibong, S. Inyang, Cynthia Onyinyechukwu Igba et al.· International Journal of Hum...· 0 citations
The proposed EBT4 film‐based IVD system, supported by open‐source software and an orthogonal dual‐scan protocol, offers a robust, cost‐effective, and time‐efficient alternative to traditional TLDs.
Zhe-Xuan Zhang, Lan Lu, G. Videtic et al.· Journal of Applied Clinical...· 0 citations
Background and purpose Proton therapy is commonly delivered for base-of-skull (BOS) tumors to minimize risk of normal-tissue injury. Novel Bragg peak FLASH may improve protection for organs at risk (OARs). We investigated if proton pencil-beam scanning (PBS) Bragg peak FLASH could achieve comparable dosimetry at ultra-...
M. Pennock, B. Selvaraj, Ching-Yun Cheng et al.· Frontiers in Oncology· 0 citations