Skip to content

An end-to-end quality assurance procedure for pelvic VMAT using optically stimulated luminescence dosimeters and an anthropomorphic phantom.

Aug 2026 · Physical and Engineering Sciences in Medicine · 0 citations · 27 references
Medicine

TL;DR

OSLD measurements in an anatomically realistic female pelvic phantom confirm that cervical cancer VMAT delivery is accurate and reproducible and support the reliability of Eclipse (v18) using the Acuros XB algorithm across high-dose, gradient, and low-dose regions.

View source

Similar papers

Open access Oct 2026

Dosimetric Validation of Ethos Online Adaptive Radiotherapy for Prostate Cancer: An End-to-End Phantom Study

Background/Objectives: Online adaptive radiotherapy (oART) re-optimizes treatment on the anatomy of the day, but automatically generated plans require dosimetric verification and dose–volume assessment. We performed an end-to-end validation of the Varian Ethos workflow for prostate cancer, including cross-adaptation be...

M. Janiszewska, M. Raczkowski · 0 citations
Open access Aug 2026

Evaluation of the environ SRS immobilization mask system for HyperArc: Dosimetric attenuation, dose calculation accuracy, and clinical setup reproducibility

Abstract Background Frameless thermoplastic masks are standard for intracranial stereotactic radiosurgery (SRS), with the Encompass (CQ Medical) widely used on the Varian HyperArc platform. A candidate mask must minimize beam attenuation, permit accurate dose calculation, and enable reproducible setup, yet these are ra...

Adi Robinson, Matthew R. Caldwell · 0 citations

Evaluation of the dosimetric leaf gap for VMAT-SBRT in small target volumes

Volumetric modulated arc therapy stereotactic body radiation therapy (VMAT-SBRT) is a highly efficient technique to treat inoperable patients. To implement the VMAT-SBRT technique in clinical applications, the commissioning process needs to be performed effectively. One of the most important steps in the commissioning...

Grit Phianpholdeesakun · 0 citations
Sep 2026

How robust are secondary dose algorithms for Patient-Specific quality assurance in modulated stereotactic Radiosurgery?

PURPOSE Accurate dose verification is essential in stereotactic radiosurgery (SRS), where small fields and steep dose gradients may amplify uncertainties, especially with complex techniques like multitarget single-isocenter VMAT. This technical note evaluated the robustness of two secondary dose calculation algorithms...

E. Mastella, K. E. Szilagyi, Joseph S. Perrine et al. · 0 citations
Open access Sep 2026

Assessing Gamma Index Sensitivity to Selected Linear Accelerator Mechanical Errors Using Various Dosimetric Systems

Background: Volumetric modulated arc therapy (VMAT) for stereotactic body radiotherapy (SBRT) involves highly modulated dose distributions and steep dose gradients, increasing the importance of patient-specific quality assurance (QA). Gamma index analysis is widely used for comparing measured and treatment planning sys...

H. Ayata, G. Aydin, E. G. Ozgur et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.