Oct 2026· Journal of Nuclear Medicine Technology· pp. jnmt.125.271723· 0 citations· 6 references
Medicine
TL;DR
Caregiver radiation exposure during patient [18F]FDG PET/CT was low and remained within acceptable limits but varied considerably with caregiver-patient proximity and the time spent with the patient.
Abstract
Caregivers who assist patients during [18F]FDG PET/CT are exposed to ionizing radiation, particularly when close physical support is required. Limited real-world data are available about the actual doses received by caregivers during routine clinical practice. This study aimed to estimate effective doses received by caregivers and determine whether exposures remained below the 1-mSv dose constraint recommended by the Australian Radiation Protection and Nuclear Safety Agency for caregivers during diagnostic procedures, consistent with International Commission on Radiological Protection recommendations. Methods: This prospective observational study included caregivers accompanying patients undergoing [18F]FDG PET/CT. Each caregiver wore a calibrated electronic pocket dosimeter that measured the personal dose equivalent in soft tissue at a depth of 10 mm below the point where the dosimeter is worn (Hp(10)), clipped to the mid-chest throughout the uptake period and during imaging. Patients received weight-based [18F]FDG activity (3.7-5.2 MBq/kg) and remained in individual uptake cubicles to minimize exposure from other injected patients. Caregiver-patient distance, measurement time, and Hp(10) were recorded. Correlations were evaluated using the Spearman rank correlation coefficient. Group comparisons were analyzed using the Kruskal-Wallis test with a Dunn post hoc analysis, and dose predictors were assessed using a generalized linear model with a γ-distribution. Results: Thirty-nine caregiver-patient pairs were included, with complete dosimetry data available for all participants. Caregivers received measurable but low Hp(10) values, although exposure varied widely on the basis of proximity and measurement time. The median caregiver dose was 0.12 mSv (interquartile range, 0.04-0.54 mSv). A strong positive correlation was observed between Hp(10) and time spent with the patient (Spearman ρ = 0.617), whereas a strong inverse correlation was observed between Hp(10) and caregiver-patient distance (Spearman ρ = -0.914). Caregivers positioned closest to patients, particularly those assisting pediatric patients, received the highest doses. Group comparisons by distance category demonstrated significant differences in exposure. Multivariate modeling confirmed that time, distance, and patient age independently contributed to caregiver dose. Conclusion: Caregiver radiation exposure during patient [18F]FDG PET/CT was low and remained within acceptable limits (<1 mSv) but varied considerably with caregiver-patient proximity and the time spent with the patient. These findings confirm that caregiver radiation exposure is strongly influenced by the time spent with the patient and the distance maintained, although close physical support is often unavoidable.
Introduction This study investigated the effect of [18F]fluorodeoxyglucose ([18F]FDG) uptake time on image quality in low-dose positron emission mammography (PEM) using kinetic modelling. Methods Fifteen malignant lesions from thirteen women newly diagnosed with breast cancer were imaged using low-dose [18F]FDG PEM. Tu...
Elliott De Benetti, Tobias Preckel, Apichart Linhananta et al.· Frontiers in Oncology· 0 citations
Objectives To evaluate and compare conventional radiation dose metrics (computed tomography dose index volume [CTDIvol] and dose length product [DLP]) with size-specific dose estimates (SSDEs) in adult patients undergoing non-contrast computed tomography (NCCT) abdomen examinations. Materials and Methods This study aim...
S. Verma, Rohit Sharma, A. Mishra et al.· Indian Journal of Radiology...· 0 citations
BACKGROUND
Computed tomography (CT) plays an essential role in diagnosing and imaging various body structures, but it continues to be one of the most frequent sources of medical radiation exposure. Diagnostic reference levels (DRLs) represent critical values for radiation dose monitoring and dose optimization.
OBJECT...
N. Alomairy, Nouf Tawashi, Reema Daghriri et al.· Health Physics· 0 citations
'Background. Computed tomography is a primary source of medical radiation exposure. Monitoring cumulative doses and assessing referral justification are essential for improving pati ent radiation safety. Materials and Methods. This retrospective observational study analyzed 2314 outpatient computed tomography scans in...
D. Baiguissova, A. Mukhamejanova, Y. Kalshabay et al.· Bulletin of Surgery of Kazak...· 0 citations
Purpose: The rise in coronavirus cases has led to an increased reliance on CT scans, which are known for delivering higher radiation exposure. This study aims to estimate organ doses (ODs) and effective doses (EDs) to evaluate the lifetime attributable risks (LARs) of cancer occurrence and mortality among patients. A t...
S. Zahabi, Saeed Bagherzadeh, K. Khoshgard et al.· Frontiers in biomedical tech...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.