Skip to content

A-043 Validation of the ImPress upper arm blood collection device for standard and advanced lipid panel markers

Oct 2026 · Clinical Chemistry · 0 citations

Abstract

Cardiovascular disease continues to be the universal leading cause of death. Preventative screening and monitoring plays an important role in mitigating risk, however, socially disadvantaged communities frequently face major challenges in receiving appropriate care. The evolution of cardiovascular risk assessment requires parallel advancements in blood collection technology. The ImPress upper arm collection device can remotely draw up to 600uL of capillary whole blood. The objective of this study was to determine if capillary whole blood collected via the ImPress device is comparable to gold standard venipuncture for lipid panel markers. Standard and advanced lipid panel markers tested include apolipoprotein A-1 (ApoA-1), apolipoprotein B (ApoB), lipoprotein(a) (Lp(a)), total cholesterol (TC), low-density lipoprotein (LDL) (calculated via Sampson equation), high-density lipoprotein (HDL), and triglycerides. All analytes were measured using the Roche cobas c502 chemistry analyzer. A minimum of 40 paired venous and capillary whole blood specimens were collected from consenting patients via venipuncture and the ImPress upper arm device, respectively. Venous and ImPress specimens were collected into lithium heparin with separating gel vacutainers (5mL) and microvettes (600uL), respectively. Samples with results outside of the analytical measuring range were excluded from analysis. Among 7 lipid panel analytes tested, the average percent bias between venous and capillary ImPress specimens ranged from -0.05% to 4.06%. Result ranges for venous specimens were: ApoA-1 (71-194 mg/dL), ApoB (29.1-129 mg/dL), Lp(a) (10.6-197 nmol/L), TC (105-250 mg/dL), calculated LDL (32.6-151 mg/dL), HDL (34.6-84.7 mg/dL), triglycerides (50.3-424 mg/dL). Bias and linear equations for paired venous and capillary ImPress specimen were: ApoA-1 (n=40), 0.7 mg/dL (0.6%), (y=1.00x +1.20; R=0.978); ApoB (n=40), 1.31 mg/dL (1.72%), (y=1.04x -1.87; R=0.995); Lp(a) (n=28), -0.03nmol/L (-0.05%), (y=1.03x -1.89; R=0.998); TC (n=45), 2.97 mg/dL (1.60%), (y=1.00x +3.81; R=0.984); calculated LDL (n=45), 1.02 mg/dL (1.00%), (y=0.98x +3.28; HDL (n=45), 0.80 mg/dL (1.43%), (y=0.97x +2.57; R=0.997); triglycerides (n=45), 6.36 mg/dL (4.06%), (y=1.04x -0.47; R=0.996). Capillary whole blood specimens collected using the ImPress upper arm device are acceptable for the clinical measurement of ApoA-1, ApoB, Lp(a),TC, LDL, HDL, and triglycerides. Remote blood collection using the ImPress upper arm device has the potential to reduce health disparities, encourage cardiovascular screening and monitoring, and propel future telehealth applications.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.