Skip to content
Preprint

Leaky-Wave Antenna for Non-Invasive Continuous Glucose Monitoring

Oct 2026 · 0 citations · 16 references
Physics

TL;DR

Preliminary in vivo experiments conducted on two human subjects show strong correlations between measured S11 phase and reference glucose levels, confirming the potential of the LWA-based sensing mechanism to track dynamic glycemic variations in a proof-of-concept setting.

Abstract

Non-invasive continuous glucose monitoring requires sensing techniques capable of delivering stable, accurate, and real-time quantification of glucose-induced dielectric variations. This paper presents a microwave-based methodology that employs a leaky-wave antenna (LWA) to launch localized traveling electromagnetic waves and estimate glucose concentration through phase measurements at a fixed operating frequency. The LWA architecture enhances electromagnetic coupling with the material under test through controlled energy leakage, enabling strong linearity and high phase sensitivity within the physiological permittivity range (relative permittivity 68-70). In vitro measurements using fetal bovine serum-glucose samples demonstrate a total phase shift of 8.51 degree across glucose concentrations from 50 to 255 mg per liter. Preliminary in vivo experiments conducted on two human subjects show strong correlations between measured S11 phase and reference glucose levels (r=0.939 and r=0.906), confirming the potential of the LWA-based sensing mechanism to track dynamic glycemic variations in a proof-of-concept setting. These results highlight the potential of the proposed approach for practical, continuous, and non-invasive glucose monitoring.

View source

Similar papers

Open access Sep 2026

Design and Characterization of a 37 GHz Millimeter-Wave Transceiver for Dielectric-Based Sensing in Aqueous Solutions

Diabetes is a chronic disease requiring frequent monitoring of blood glucose levels, while conventional invasive techniques remain painful and inconvenient. In this work, we present a compact millimeter-wave (mm-wave) transceiver operating at 37 GHz for non-invasive glucose sensing based on variations in the dielectric...

Vedat Çavlu · 0 citations
Nov 2026

Modeling Blood Permittivity with a Modified Cole-Cole Framework.

Accurate, non-invasive estimation of blood glucose and glycated hemoglobin (HbA1c) remains a key challenge in biomedical sensing. This study introduces a novel electromagnetic framework for modeling the dielectric response of blood to glucose variations, focusing on the real part of permittivity (ε') across 0.1-20 GHz....

Z. A. Abdul Hassain, Malik J. Farhan, T. A. Oleiwi · 0 citations
Open access Sep 2026

Simultaneous band-pass Raman spectroscopy for robust noninvasive continuous glucose monitoring

The rising incidence of diabetes underscores an urgent need for accurate, user-friendly, and truly noninvasive continuous glucose monitoring (CGM). Raman spectroscopy is an attractive foundation for noninvasive CGM because it is label-free and offers direct molecular specificity to glucose. Building on our previous s...

L. Foglia, A. Bresci, Youngkyu Kim et al. · 0 citations
Open access Sep 2026

Hygieia: A Wearable Metamaterial Patch for Calibration-free Carotid Hemodynamics Monitoring

Long-term, continuous cardiac monitoring is essential for early detection and risk prediction of cardiovascular diseases. Recently, electromagnetic-based monitoring methods have gained attention because they are not affected by skin tone or contact force compared to optical or pressure-based methods. While existing sys...

Cheng-Han Jiang, Shi-Bo Zhang, Bo Yang et al. · 1 citation
Open access 2026

Non-Contact Heart Rate Estimation From Carotid Pulse Using Ultra-Wideband mmWave Loaded-Slot Antenna

Non-contact carotid pulse monitoring is a promising alternative to conventional contact-based methods by enabling continuous remote monitoring while improving patient comfort, reducing infection risk, and supporting telehealth applications. On the other hand, reliable contact-free detection of the carotid pulse remains...

Sagiru Gaya, K. Khalaf, A. S. M. Alqadami et al. · 0 citations
Open access 2021

Non-Invasive Blood Glucose Meter

The glucose concentration in the range from 111-330 mg/dl represents a diabetic patient. it causes physical impairment of vital organs. presently, non-invasive blood glucose monitoring device that uses the blood dielectric and impedance properties is becoming popular for diabetes detection. a realistic reusable low-cos...

Mahesh Sheth, M. Jadhav, Sunita Deshmukh · 0 citations