Preliminary in vivo experiments conducted on two human subjects show strong correlations between measured S11 phase and reference glucose levels, confirming the potential of the LWA-based sensing mechanism to track dynamic glycemic variations in a proof-of-concept setting.
Abstract
Non-invasive continuous glucose monitoring requires sensing techniques capable of delivering stable, accurate, and real-time quantification of glucose-induced dielectric variations. This paper presents a microwave-based methodology that employs a leaky-wave antenna (LWA) to launch localized traveling electromagnetic waves and estimate glucose concentration through phase measurements at a fixed operating frequency. The LWA architecture enhances electromagnetic coupling with the material under test through controlled energy leakage, enabling strong linearity and high phase sensitivity within the physiological permittivity range (relative permittivity 68-70). In vitro measurements using fetal bovine serum-glucose samples demonstrate a total phase shift of 8.51 degree across glucose concentrations from 50 to 255 mg per liter. Preliminary in vivo experiments conducted on two human subjects show strong correlations between measured S11 phase and reference glucose levels (r=0.939 and r=0.906), confirming the potential of the LWA-based sensing mechanism to track dynamic glycemic variations in a proof-of-concept setting. These results highlight the potential of the proposed approach for practical, continuous, and non-invasive glucose monitoring.
Diabetes is a chronic disease requiring frequent monitoring of blood glucose levels, while conventional invasive techniques remain painful and inconvenient. In this work, we present a compact millimeter-wave (mm-wave) transceiver operating at 37 GHz for non-invasive glucose sensing based on variations in the dielectric...
Vedat Çavlu· Gazi Üniversitesi Fen Biliml...· 0 citations
Accurate, non-invasive estimation of blood glucose and glycated hemoglobin (HbA1c) remains a key challenge in biomedical sensing. This study introduces a novel electromagnetic framework for modeling the dielectric response of blood to glucose variations, focusing on the real part of permittivity (ε') across 0.1-20 GHz....
Z. A. Abdul Hassain, Malik J. Farhan, T. A. Oleiwi· Journal of Visualized Experi...· 0 citations
The rising incidence of diabetes underscores an urgent need for accurate, user-friendly, and truly noninvasive continuous glucose monitoring (CGM). Raman spectroscopy is an attractive foundation for noninvasive CGM because it is label-free and offers direct molecular specificity to glucose. Building on our previous s...
L. Foglia, A. Bresci, Youngkyu Kim et al.· npj Biosensing· 0 citations
Long-term, continuous cardiac monitoring is essential for early detection and risk prediction of cardiovascular diseases. Recently, electromagnetic-based monitoring methods have gained attention because they are not affected by skin tone or contact force compared to optical or pressure-based methods. While existing sys...
Cheng-Han Jiang, Shi-Bo Zhang, Bo Yang et al.· Proceedings of the ACM on In...· 1 citation
Non-contact carotid pulse monitoring is a promising alternative to conventional contact-based methods by enabling continuous remote monitoring while improving patient comfort, reducing infection risk, and supporting telehealth applications. On the other hand, reliable contact-free detection of the carotid pulse remains...
Sagiru Gaya, K. Khalaf, A. S. M. Alqadami et al.· IEEE Access· 0 citations
The glucose concentration in the range from 111-330 mg/dl represents a diabetic patient. it causes physical impairment of vital organs. presently, non-invasive blood glucose monitoring device that uses the blood dielectric and impedance properties is becoming popular for diabetes detection. a realistic reusable low-cos...
Mahesh Sheth, M. Jadhav, Sunita Deshmukh· Journal of Science & Tec...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.