Skip to content
Open access

3D printed robotic tooling for fluoroscopy-guided vascular access: emerging implications for cardiology practice

Oct 2026 · European Heart Journal · Vol 47 · 0 citations

TL;DR

A radiation efficiency paradox in femoral arterial access is quantified, where fluoroscopy time increases modestly but operator dose rate falls, and dose-per-minute metrics that better reflect staff risk are proposed that better reflect staff risk.

Abstract

Interventional cardiologists are exposed to occupational radiation during fluoroscopy-guided procedures, because the hands are closest to the radiation source they receive the highest exposure, with the eyes being the second most exposed due to their proximity. Conventional protective measures such as lead aprons, thyroid shields, and optimised beam positioning offer partial mitigation, yet maintaining adequate working distance from the x-ray source during hands-on needle and guidewire work remains physically impractical without robotic assistance. A robotic mechanism incorporating a 3D printed needle and guidewire insertion tool has been designed to overcome this limitation. To quantify a radiation efficiency paradox in femoral arterial access, where fluoroscopy time increases modestly but operator dose rate falls, and to propose dose-per-minute metrics that better reflect staff risk. Twelve fluoroscopy guided femoral arterial punctures were performed in a controlled swine model by one experienced operator, six using conventional workflow and six using a robotic 3D printed needle and guidewire platform. Per-procedure dose (mSv) was recorded at seven operator sites (fingers, wrist, eyes, left and right arms, left and right legs) using active personal dosimeters. Fluoroscopy time, access success, access-site events, and navigating hand distance from the radiation source were recorded. Radiation efficiency endpoints were derived: (1) cumulative multi-site dose per minute of fluoroscopy and (2) combined hand dose per minute (fingers plus wrist). Fluoroscopy time increased from 5.166 ± 1.169 to 6.511 ± 1.751 min with the platform, while navigating hand distance increased from 5 ± 1.029 to 250 ± 0.453 mm. Dose decreased significantly at every monitored site (all p ≤ 0.021). Finger and wrist doses fell from 1.071 ± 0.192 to 0.213 ± 0.052 mSv and from 0.726 ± 0.174 to 0.142 ± 0.070 mSv, respectively (both p < 0.001).When normalised to time, cumulative multi-site dose rate fell from 0.483 to 0.112 mSv/min, a 76.9% reduction, and combined hand dose rate fell from 0.348 to 0.055 mSv/min, an 84.3% reduction. Access success was 6/6 in both conditions with low, comparable complication counts. In fluoroscopy guided femoral access, longer fluoroscopy time can coexist with markedly lower occupational exposure intensity when procedure geometry shifts the operator away from the scatter field. Including dose-per-minute metrics, especially for hand exposure, in addition to total dose and fluoroscopy time could enable clearer comparisons between devices and techniques and support more effective strategies to reduce occupational risk.3D Printed robotic platform

Read PDF

Similar papers

Oct 2026

Occupational Radiation Exposure During Robotic-Assisted Navigational Bronchoscopy: A Prospective Real-Time Dosimetry Study.

BACKGROUND Robotic-assisted bronchoscopy (RAB) uses fluoroscopy and cone-beam CT (CBCT), which can expose procedural staff to ionizing radiation. Real-time, role-specific occupational dosimetry data from live RAB procedures remain limited. METHODS We prospectively collected continuous personal dosimetry from attendin...

V. Hegde, T. Odeh, S. Windham et al. · 0 citations
Open access Sep 2026

Simulation-based dosimetric analysis of surgeon radiation exposure during robotic-assisted versus conventional URS

Fluoroscopy during urinary stone surgery exposes patients and operating staff to ionizing radiation. This study aims to model and estimate surgeon radiation dose in robotic-assisted versus conventional ureteroscopy (URS) using an experimental simulation to evaluate the potential safety advantages of robotic systems. A...

R. Ergul, Ş. N. İnceoğlu, B. Özdemir et al. · 1 citation
Nov 2026

First in-human feasibility evaluation of an integrated guidewire Seldinger system with enhanced ultrasound feedback for central venous access

Central venous access procedures are among the most frequently performed invasive procedures worldwide, yet they remain associated with measurable complication rates and technical challenges. Despite the widespread adoption of ultrasound guidance, limitations in needle visualization, needle stability and workflow i...

T. Allen, Vikram R. Shaw, Adrian Ebner et al. · 0 citations
Open access Oct 2026

Fluoroscopic Catheter-Tip Positioning During Internal Jugular TIVAD Placement in Breast Cancer: A Two-Center Retrospective Cohort Study

Background/Objectives: Fluoroscopy permits direct assessment of catheter course and tip position during totally implantable venous access device (TIVAD) placement. We compared left- and right-sided internal jugular vein (IJV) port placement in breast cancer. Methods: This retrospective two-center cohort included 836 ul...

Ze-Yang Fan, Kai Yang · 0 citations
Review Open access Oct 2026

Early Experience of Fiber Optic RealShape Technology in Endovascular Interventions for Peripheral Artery Disease: A Prospective Single-Center Study.

OBJECTIVE Interventions in peripheral artery disease (PAD) have changed significantly over the past decades. Most centers have adopted an endovascular-first strategy resulting in an increased radiation exposure, especially for the treatment team. Fiber Optic RealShape (FORS) technology uses laser light instead of fluor...

J. Klaassen, S. Lodema, J. V. van Herwaarden et al. · 0 citations
Open access Nov 2026

Real-time XR-based 6-DOF catheter tracking enhances cardiac intervention navigation efficiency and depth perception

Despite advances in 3D ultrasound, most percutaneous cardiac interventions still rely on 2D visualization, limiting depth perception and spatial understanding. To address this challenge, we developed an Extended Reality (XR)-based platform that enables real-time six-degree-of-freedom (6-DOF) catheter tracking and visua...

Mohsen Annabestani, Sandhya Sriram, Andrew Kuzemczak et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.