Misalignment Analysis of a Single-Stage Wireless Power Transfer Converter Under Constant Current Operation
Abstract
Wireless power transfer (WPT) has emerged as an attractive solution for EV charging due to its convenience and safety. However, coil misalignment between the transmitting $\left(T_{x}\right)$ and receiving $\left(R_{x}\right)$ coils reduces magnetic coupling and transferable power of the system. This paper investigates the misalignment performance evaluation of a single-stage WPT converter operating in constant current (CC) mode. The converter is developed and simulated in MATLAB/Simulink to evaluate the impact of coil misalignment on system performance. The system has rated output of 360 W with switching frequency of 85 kHz. Misalignment is modeled by reducing the mutual inductance $(M)$ between the coils while keeping the self inductance constant. The simulation results show that the converter can maintain approximately 80% of the rated load current (4 A) under the considered misalignment condition before the CC regulation fails.