Skip to content
Open access

Influence of particle size and flow conditions on retention in vuggy porous media

Oct 2026 · Scientific Reports · 0 citations

Abstract

This study investigates the effect of particle size and flow conditions on particle retention in vuggy porous media by monitoring the changes in the rock porosity using temporal computed tomography (CT) scans during the injection of a glass bead suspension. Synthetic glass bead cores are fabricated by sintering glass beads to create a proxy core sample with known petrophysical properties. The core is vertically mounted in a dynamic core flooding setup which is placed inside a medical CT scanner, and fine-sized particles (40 and 125 $$\upmu $$ m diameter) are injected at different flow rates (40 and 60 cm 3 /min) and injected particle concentrations (0.5 and 1.0 wt%). Unlike previous studies that rely primarily on initial and final petrophysical characterization, this study systematically examines the coupled effects of flow rate, particle size, and particle concentration on the spatiotemporal evolution of particle retention in a controlled vuggy pore structure. A baseline CT scan is conducted on the core, and subsequent temporal scans are conducted to determine the evolution of porosity and the spatial distribution of the trapped particles. Results indicate that the injected particle size is the primary factor governing the porosity change of the system, with the larger injected particle size creating an external filter cake and resulting in $$\sim $$  50% reduction in porosity at the inlet. The porosity loss is focused at the vug inlet, with the region before the vug exhibiting double the porosity loss of the region after the vug. A faster injection rate and higher injected particle concentration cause higher particle-particle collisions, resulting in porosity loss of up to 6% near the inlet. Retention is focused at the vug inlet at the high flow rate and at the vug outlet at the lower flow rate. The vug volume is observed to decrease continuously with time, with volume reduction of up to 3% observed. A lower injected particle concentration results in slower, and generally, lower total retention. The temporal CT observations reveal that particle retention and the associated pore-space alteration are highly non-uniform and evolve dynamically with injection conditions, demonstrating the importance of spatially and temporally resolved characterization for understanding particle transport in heterogeneous vuggy media. Furthermore, sample-to-sample variability was observed, most notably in the inlet porosity in sample 40-1.0-60, highlighting the variability that can occur even under controlled experimental conditions.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.