Skip to content
Open access

Comparison of additive and subtractive digital workflow for the accuracy of removable occlusal stabilization-splints – an in-vitro study

Oct 2026 · Clinical Oral Investigations · Vol 30 · 0 citations · 45 references
Medicine

TL;DR

Manufacturing of removable occlusal splints with CAD/CAM appears to be a precise and comfortable option with deviations comparable to previous in-vitro studies of digitally manufactured occlusal splints.

Abstract

Patients with stage IV periodontitis often require additional rehabilitation of the compromised dentition due to anatomical and functional consequences of tooth loss. Removable occlusal splints can be helpful in these advanced cases. This in-vitro study compared the accuracy and internal fit of removable occlusal splints fabricated by 3D-printing and milling from a standardized STL-file. A standard-tessellation-language (STL)-file was created from a scanned master-model of the upper jaw and used for production of forty identical splints. Twenty splints were 3D-printed and twenty were milled. Subsequently all splints were rescanned, new STL-files resulted, which were compared with the original STL-file. Accuracy of both methods were assessed at 42 predefined points. Distances from vestibular to vestibular (v-v) respectively palatinal to palatinal (p-p) between molars were compared. Mann-Whitney-test was used for comparison (p < 0.05). Mean values were 43.9 ± 31.29 μm (3D) and 22.0 ± 18.46 μm (milled), with a significant difference between groups (p < 0.001, Mann-Whitney). The 3D technique resulted generally in a contraction (mean (SD) v-v: mean − 13.0 μm (± 92.16); p-p: -9.3 μm (± 123.03)). With the milled technique, a contraction vestibular-to-vestibular (-4.0 μm (± 53.63)), but palatinal-to-palatinal an expansion was measured (38.5 μm (± 33.86)). Vestibular, differences between groups were not significant (p = 0.862, Mann-Whitney), but palatinal at the second molar (p < 0.001, Mann-Whitney). Both techniques showed deviations comparable to previous in-vitro studies of digitally manufactured occlusal splints. Less deviations were found in posterior areas of the dental arch with milled manufacturing. Manufacturing of removable occlusal splints with CAD/CAM appears to be a precise and comfortable option.

Read PDF

Similar papers

Open access Sep 2026

Comparison of 3D-Printed Versus Analog Occlusal Splints on Patient-Reported Outcomes

Background: Occlusal splints are a widely used, reversible option for the management of temporomandibular disorders (TMD) and bruxism, and can now be produced either through conventional analog procedures or through fully digital additive workflows. Evidence on how patients actually perceive the two device types is sca...

R. Bucci, A. Michelotti, Martina D'Antonio et al. · 0 citations
Review Open access Sep 2026

Digital complete removable denture (CRD, PAT): state of the art and contribution of digital workflows

Digital CRDs provide clinical performance equivalent to or superior to conventional techniques in terms of fit accuracy, retention, and occlusal accuracy and hybrid workflows currently represent the safest and most widely adopted compromise.

Thiermo Sow, Saad Aroussi, Deo Hounyetin et al. · 0 citations
Open access Sep 2026

Effect of Remaining Teeth on Complete Arch Implant Scanning: An In Vitro Comparison of Interabutment Deviations in Two Digital Workflows

This in vitro study evaluated whether the presence of four remaining teeth affected the reproduction of interabutment spatial relationships by two intraoral scanning systems. A single three-dimensionally printed maxillary master model containing four implant analogues connected to Mini Conical Abutments was evaluated s...

Lucas David Galvani, Kathleen Lemos Soares, Jailson Junior Rodrigues Oliveira et al. · 0 citations
Open access Oct 2026

Evaluation And Comparison of Flexural Strength of Two Different Posterior Provisional Crowns Fabricated Using CAD-CAM and 3D Printing: An invitro study

Background: Provisional restorations play an important role in fixed prosthodontics in maintaining function, esthetics and protecting prepared teeth until permanent restorations are applied. Digital dentistry is becoming more and more common, and computer-aided design/computer-aided manufacturing (CAD-CAM) milling and...

K. N. Chowdary, Muvva Suresh, D. Babu et al. · 0 citations
Open access Nov 2026

Effect of Non-Splinting Techniques and Non-Calibrated Implant Scan Body Systems on the Accuracy of Complete-Arch Implant Scans: A Comparative Clinical Study.

PURPOSE To evaluate the accuracy of complete-arch implant scans obtained using non-splinting and non-calibrated implant scan body (ISB) methods captured by an intraoral scanner (IOS) with 2 scanning patterns with and without artificial intelligence (AI)-based tools. MATERIALS AND METHODS A patient with an edentulous...

Theodoros Tasopoulos, Marta Revilla-León, A. B. Barmak et al. · 0 citations
Open access Oct 2026

An innovative approach for retreatment of prosthetically failing implant-supported fixed prostheses with a complete digital workflow: A technique report.

Complications in fixed implant prostheses are frequently encountered and can negatively impact patients' quality of life. This technique outlines a complete digital workflow for the remake of full-mouth, implant-supported, cement-retained restorations necessitated by esthetic and functional impairments. For the digital...

S. Karaca, Fatmanur Demir Boz, Kıvanç Akça · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.