Long-term changes in pacemaker stimulation burden and its influence on clinical outcomes after transcatheter aortic valve implantation: a multicenter study
Oct 2026· European Heart Journal· Vol 47· 0 citations
TL;DR
It is indicated that patients with persistently high pacing burden should may benefit from structured cardiological follow-up, including optimization of pacing parameter, and a decreasing pacing rate (high/low) was significantly associated with a lower risk of MACE.
Abstract
Permanent pacemaker (PPM) implantation remains a common complication after transcatheter aortic valve implantation (TAVI). The long-term clinical implications of pacemaker dependency following TAVI remain a subject of ongoing debate and investigation. In a previous single-center study from our group, examining the relationship between TAVI implantation depth and subsequent pacing burden, we found that approximately one-third of patients with initially low PPM stimulation rates experienced a clinically relevant increase to >20% ventricular pacing within the first three months following TAVI. This temporal evolution suggests progressive conduction system injury and raises concerns about potential delayed adverse effects on cardiac function and clinical outcomes.
This multicenter study investigated long-term changes in ventricular pacing burden and their association with mortality and major adverse cardiovascular events (MACE).
Patients receiving PPM after TAVI between 2009 and 2024 at two tertiary centers were retrospectively analyzed. Patients were categorized by ventricular pacing burden (>20% defined as high) at baseline and follow-up: high/high (n=309), high/low (n=103), low/high (n=143), and low/low (n=216). Both self-expanding and balloon-expandable valves were included. Pacemaker burden was assessed at discharge and three months, and five-year outcomes, including mortality and major adverse cardiovascular events, were recorded.
A total of 771 patients who underwent TAVI followed by PPM implantation were analyzed (median age 82 years; 49.5% female). Patients were categorized by ventricular pacing burden at baseline and follow-up: high/high (n=309), high/low (n=103), low/high (n=143), and low/low (n=216). At 5 years, all-cause mortality did not differ significantly among groups (log-rank p=0.310). In contrast, the composite MACE endpoint differed significantly (p=0.038). Compared with the low/low group, hazard ratios for 5-year MACE were 0.74 (95% CI 0.52–1.06) for low/high, 0.61 (95% CI 0.40–0.93) for high/low, and 0.97 (95% CI 0.69–1.35) for high/high, with the high/low group exhibiting the lowest cumulative MACE incidence.
Approximately 30% of patients experienced changes in ventricular pacing burden over time. While neither initial nor temporal pacing patterns affected overall mortality, a decreasing pacing rate (high/low) was significantly associated with a lower risk of MACE. These findings indicate that patients with persistently high pacing burden should may benefit from structured cardiological follow-up, including optimization of pacing parameter.
BACKGROUND
Pacemaker implantation after transcatheter aortic valve replacement (TAVR) is common and has been associated with adverse clinical outcomes. Cardiac physiological pacing (CPP) may preserve ventricular synchrony and reduce heart failure (HF) events compared with right ventricular pacing (RVP).
OBJECTIVES
Th...
F. Díez-Delhoyo, Jorge Sanz-Sánchez, Guillem Muntané-Carol et al.· JACC: Cardiovascular Interve...· 1 citation
Pacemaker dependency and the impact of ventricular pacing burden after Transcatheter Aortic Valve Replacement (TAVR) in patients with pre-existing pacemakers remain poorly defined.
To assess changes in pacemaker dependency after TAVR, identify predictors of 1-month dependency, and evaluate whether Ventricu...
O. Ayyad, H. A. Khadija, A. Mahamid et al.· European Heart Journal· 0 citations
Permanent pacemaker implantation (PPI) remains a frequent complication after transcatheter aortic valve implantation (TAVI), yet its long-term prognostic impact remains debated.
To determine the association between new PPI after TAVI and long-term mortality and heart failure (HF) rehospitalization using re...
F. Jordan, N. Formenti, T. Stolte et al.· European Heart Journal· 0 citations
Conduction system disorders are frequent complications following transcatheter aortic valve implantation (TAVI), with persistent conduction abnormalities often necessitating permanent pacemaker (PPM) implantation.
To evaluate the predictive value of isolated PR interval prolongation for PPM implantation wi...
T. Serban, M. Salis, A. Papa et al.· European Heart Journal· 0 citations
Studies comparing conduction system pacing (CSP) with conventional pacemaker (PM) implantation after transcatheter aortic valve implantation (TAVI) remain scarce.
To evaluate the 1-year outcomes of patients undergoing CSP versus conventional PM after TAVI.
In this prospective, observational, multice...
T. Serban, S. Stortecky, P. Krisai et al.· European Heart Journal· 0 citations
The comparative long-term clinical outcomes of catheter ablation versus pacemaker implantation in patients with atrial fibrillation(AF) and sick sinus syndrome(SSS) remain controversial.
This study aims to evaluate the long-term clinical outcomes between catheter ablation and permanent pacemaker implantati...
X. Yang, J. Zhao, K. Chen et al.· European Heart Journal· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.