Oct 2026· Journal of Chromatography A· Vol 1790, pp.
467564
· 0 citations· 45 references
Medicine
TL;DR
A sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of 74 antibiotics from multiple classes in fine particulate matter (PM2.5), providing a comprehensive workflow for monitoring airborne antibiotics and supporting subsequent exposure and environmental-occurrence studies.
Abstract
The increasing occurrence of antibiotics in the environment has raised concerns about their atmospheric transport, human exposure, and potential contribution to antibiotic resistance dissemination. In this study, a sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of 74 antibiotics from multiple classes in fine particulate matter (PM2.5). Key chromatographic and sample-preparation parameters were systematically optimized. Optimal performance was achieved using a T3 chromatographic column, mobile phases containing 0.1% (v/v) formic acid, Oasis HLB cartridges for solid-phase extraction, 0.1 mol/L disodium ethylenediaminetetraacetate, and methanol containing 1% (v/v) formic acid as the elution solvent. These conditions improved extraction efficiency, chromatographic performance, and quantitative sensitivity while reducing matrix-related interference. The validated method yielded accuracy values of 69.7%-131.7% and relative standard deviations of 1.0%-18.1% at three fortification levels, with estimated method quantification limits as low as 0.37 pg/m3. The method was applied to 29 ambient PM2.5 samples collected over 24-h periods in Beijing. Twenty-two antibiotics were detected above their respective method detection limits, with concentrations reaching 121.38 pg/m3. Seven compounds exhibited detection frequencies above 50%, and roxithromycin was detected in all samples. Oxytetracycline showed the highest mean concentration among the quantifiable results, at 14.48 pg/m3. Compared with previously reported methods that generally cover fewer antibiotic classes or focus on conventional environmental matrices, the proposed method enables sensitive and simultaneous determination of a broad range of antibiotics in the analytically challenging PM2.5 matrix. It therefore provides a comprehensive workflow for monitoring airborne antibiotics and supporting subsequent exposure and environmental-occurrence studies.
This study describes the development and validation of an ultra‐performance liquid chromatography‐mass spectrometry (UPLC‐MS/MS) method for the detection, quantification, and confirmation of clopyralid (CLPD) and its conjugate in diverse plant matrices (high water, acid, oil, and protein). The workflow combines the...
A robust, sensitive and stability-indicating HPLC
method was developed and validated for the
simultaneous quantification of mirdametinib and its
impurities in pharmaceutical formulations, with a
special focus on MS/MS-based structural
characterization of degradation products. The
chromatographic optimization was achiev...
P. Prasadrao, Pavani Peddi, Mounica Lella et al.· Research journal of chemistr...· 0 citations
To enable rapid and accurate determination of sulfonamide residues in animal-derived foods, a method was developed for the simultaneous analysis of 20 sulfonamides by ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) combined with a FaVEx one-step cleanup column, using pork as a repres...
The established UHPLC-MS/MS method is simple, highly specific, and sensitive, offering a reliable approach for production monitoring, routine batch analysis, and confirmatory testing of FBZ and metabolites in animal-derived foods.
Can Guo, Hai-Feng Yang, Shou-Ying Wang et al.· Food Additives and Contamina...· 0 citations
Application of the validated method to commercial herbal weight-loss supplements successfully identified products adulterated with sibutramine and desmethylsibutramine, and all positive findings were independently confirmed by high-resolution mass spectrometry.
D. Minh, L. A. Thi, L. Duyen et al.· RSC Advances· 0 citations
A sensitive and reliable ultra-high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of ibuprofen in plasma to investigate the pharmacokinetics of ibuprofen after oral administration of ibuprofen sustained-release capsules.
Mei-Ah Yang, Kui He, Yu-Jie Mo et al.· Acta Chromatographica· 0 citations