Trajectory Calibration Using a Single Point Absorber for Single-Transducer Circular-Scanning Photoacoustic Tomography: A Theoretical and Simulation Study
Accurate spatial-resolution characterization of flat-panel detectors at megavoltage energies is difficult due to long-tailed cross-talk. Conventional measurements at high energy using line-pair gauges or knife-edge phantoms require expensive, carefully fabricated objects and precise alignment, and despite these, scatte...
Accurate projectile velocity measurement is essential for weapon system evaluation, where laser screen velocimetry (LSVM) systems face inherent limitations owing to photoelectric response inconsistencies between detection screens, causing target deviation errors that compromise the measurement precision. In this study,...
Wen-Bo Chu, Bin Zhang, Yuan Li et al.· Advanced Photonics Research· 0 citations
High-resolution two-dimensional dosimetry is important for radiotherapy quality assurance. Scintillating fiber tomodosimetry is attractive because of its near water equivalence and fine spatial sampling, but most implementations rely on detector rotation. Here, we report Monte Carlo simulations of a static multi-stack...
Sajjad Ahmad Khan, Luc Beaulieu, Louis Archambault· Journal of Physics, Conferen...· 0 citations
Detector shifting is used in industrial cone-beam computed tomography to reduce ring artifacts, but the resulting detector motion can vary nonuniformly across projection views and produce detector positions that cannot be represented by fixed offsets. Although analytical reconstruction can accommodate this motion, appr...
Doga Topcicek, Sharmin Majumder, Whitney A. Poling et al.· 0 citations
Objective. Gamma Knife cone-beam computed tomography (CBCT) images are deteriorated by cone-beam artifacts whose magnitude increases along the superior direction. In this study, a novel scan trajectory compatible with the Gamma Knife CBCT system is optimized to reduce cone-beam artifacts, with the aim to replace the cu...
Alexandra Alain-Beaudoin, H. Nordström, Luc Beaulieu et al.· 1 citation· ⚡1
Low-finesse Fabry-Pérot (F-P) cavities are attractive for high-precision micro-displacement measurement (MDM), but residual multiple reflections introduce periodic nonlinear error during quadrature demodulation. In this work, a reflective-sphere-based low-finesse F-P cavity and a model-based periodic nonlinear error co...
Ju Wang, X. Chen, Hao Luo et al.· Optics Express· 0 citations