Flexural behaviour of cold-formed steel sigma-shaped welded built-up I-beams under four-point bending: experimental, numerical and DSM design evaluation
Abstract
ABSTRACT This study investigates the flexural behaviour and ultimate strength of cold-formed steel sigma-shaped welded built-up I-sections through experimental, numerical and analytical approaches. Six built-up sigma I-sections with varying depths (150,200, and 250 mm) and thickness (1.6 and 2 mm) were tested under four- point bending over a 3000 mm span. The material properties were determined from tensile coupon tests (yield strength: 438 MPa). Finite element analyses were performed using ABAQUS incorporating material and geometric nonlinearity, demonstrating excellent correlation with experimental results. All the specimens exhibited local buckling in the compression flange as the predominant failure mode, followed by distortional buckling. Increasing section depth resulted in higher flexural strength (65% increase from 150 mm to 250 mm compared to thickness increase (12–25%). The Direct Strength Method (DSM) of AISI S100 provided conservative estimates of strength, underpredicting the experimental values by 25–30%. This under prediction is attributed to the DSM’s inability to capture post buckling reserve strength and the stabilizing effect of intermediate web stiffeners in sigma sections. The findings confirm that sigma-shaped built up CFS sections with web stiffeners offer improved flexural capacity and buckling resistance compared to lipped channel sections, making them viable alternatives for sustainable structural design with weight-to-strength ratios.