Skip to content
Open access

Empirical Assessment of Geometric Accuracy of Underwater Lidar in Tropical Shallow Waters

Jul 2026 · The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences · 0 citations · 6 references

Abstract

Abstract. This study empirically evaluates the geometric accuracy of point cloud data acquired using an underwater lidar (ULi) system in a tropical shallow water environment. The field test was conducted in the tropical waters of the Seribu Islands, Indonesia, characterised by relatively low turbidity. Terrestrial laser scanning (TLS) and close-range photogrammetry were employed as independent reference datasets. Geometric discrepancies between datasets were quantified using the multiscale model-to-model cloud comparison (M3C2) algorithm, and errors were statistically characterised using the median and median absolute deviation (MAD) to ensure robustness under non-normal distributions. The results indicate that the error of ULi relative to TLS is 0.008 ± 0.012 m, while the error relative to photogrammetry is 0.006 ± 0.013 m. In comparison, the discrepancy between photogrammetry and TLS is smaller, at 0.002 ± 0.004 m. Dimensional analysis of an acoustic Doppler current profiler (ADCP) frame further shows that ULi agrees with TLS and photogrammetry within the millimetre to centimetre range (0.000–0.015 m). Larger deviations in specific segments are attributed to local effects, including edge-related artefacts. Overall, the results demonstrate that ULi provides reliable geometric measurements in shallow-water conditions with low turbidity. Despite slightly lower accuracy compared to terrestrial methods, the system shows potential for underwater mapping applications, particularly in shallow water environments.

Read PDF

Similar papers

Open access Jul 2026

Accuracy assessment of bathymetric LiDAR using planar reference geometries and total station measurements

Abstract. Airborne laser bathymetry (ALB) is an efficient and accurate tool for mapping submerged environments, particularly shallow water bodies that are difficult to access with surface vessels. Modern ALB systems can achieve accuracies comparable to SONAR. However, multiple factors, including geo-referencing, water surface modelling, and range measurements, influence the resulting point cloud, making analytical error propagation challenging. Empirical evaluation against reference data is therefore essential, but difficult: ALB accuracy is typically in the low centimetre range, requiring reference data of equal or higher accuracy. Robotic total stations enable acquisition of underwater reference data for shallow water depths, e.g., up to 4.5m, with expected accuracies between 3mm to 10mm, depending on water depth, which approaches the inherent accuracy of ALB and limits the evaluation significance. In this study, we assess a UAS-based ALB data set from a mountain lake in Austria using reference planes and points acquired by robotic total stations. We separate the accuracy analysis into trueness and precision to isolate the effects of geo-referencing and water surface modelling from the intrinsic uncertainty of the LiDAR sensor. The results show that geo-referencing introduces the largest systematic bias, while the precision of the ALB data remains approximately 1 cm to 2 cm, even for submerged measurements. These findings demonstrate the high accuracy of state-of-the-art ALB systems and provide a framework for rigorous accuracy assessment in shallow aquatic environments.

Lucas Dammert, Jan Rhomberg-Kauert, P. Amon et al. · 0 citations
Review Open access Jul 2026

Evaluation of an underwater laser scanner and an air-borne laser scanner in coastal shallow waters

Abstract. Next to the known photogrammetric or acoustic measurement techniques, nowadays LiDAR is a promising option for high-resolution surveys or monitoring of underwater structures in low turbid and shallow waters. The objective of this investigation is to determine the performance of an underwater laser scanner and an air-borne bathymetric laser scanner for mobile data acquisitions. For this purpose, the underwater LiDAR (ULi) from Fraunhofer IPM is installed on a vessel. To enable the registration and georeferencing of the scan data, ULi is added by an Inertial Navigation System (INS) and two GNSS antennas. On the other hand, the air-borne bathymetric laser scanner (ABS) is integrated into an unmanned aerial system (UAS). Both systems are used to survey in the same measurement area to acquire comparable data sets. With the selected measurement settings, both systems can penetrate through water for more than 10 m and are able to resolve small underwater structures. Caused by shorter measurement ranges, ULi offers a point density which is approximately four times higher than the ABS and is able to resolve vertical underwater structures. The advantage of the UAS mounted ABS is that it can survey in shallow areas which cannot be accessed by vessels.

Annette Scheider, Sethmiya Herath Mudiyanselage, Christoph S. Werner et al. · 0 citations
Review Open access Jul 2026

Mapping at the Boundary: Simultaneous Above- and Underwater Surveying of Rocky Coastal Environments with an Uncrewed Surface Vehicle

Abstract. Mapping at the air–water interface in shallow coastal environments remains challenging due to the need to integrate heterogeneous datasets acquired under different geometric and operational conditions. This study presents a modular uncrewed surface vehicle (USV)-based system for simultaneous above- and underwater photogrammetric surveying supported by differential GNSS positioning. The system integrates a rigid multi-camera configuration, GNSS time synchronization, and a direct georeferencing workflow based on trajectory interpolation and lever-arm calibration. Experimental results from a rocky coastal site in Sardinia (Italy) show that underwater photogrammetry can achieve centimetric absolute accuracy (2–4 cm horizontally and ~8 cm vertically) without underwater ground control points. The USV enables controlled and repeatable acquisition in very shallow environments, while UAV photogrammetry complements the reconstruction of the emerged area. Limitations related to image quality and refraction effects are discussed. The system represents a flexible and scalable solution for integrated coastal mapping and monitoring.

Sergey Khokhlov, F. Menna, E. Nocerino · 0 citations
Open access Jul 2026

Refraction-aware integrated Georeferencing of bathymetric Laser Scanning Data

Abstract. Bathymetric Laser Scanning (BLS) enables high-resolution mapping of underwater topography using green-wavelength laser pulses that penetrate the water column. However, precise georeferencing of the BLS data is affected by refraction at the air–water interface, which displaces submerged features and affects conventional strip adjustment methods. This paper introduces an integrated refraction-aware georeferencing workflow that combines refraction correction with trajectory and boresight optimization within a unified adjustment framework. Implemented using the scientific OPALS laser scanning software, the workflow starts with direct georeferencing of uncorrected laser returns, derives a water surface model, applies Snell’s law-based refraction correction, and performs iterative strip adjustment until convergence. The approach was validated using UAV-borne topo-bathymetric LiDAR data from Lake Alm (Almsee) in Upper Austria, captured with a RIEGL VQ-840-GE sensor system. Comparative analysis across multiple processing scenarios demonstrates that the proposed integrated method significantly improves internal consistency between overlapping flight strips. The residual height discrepancies, quantified by the median absolute deviation (σMAD), were reduced from 4.5 cm using standard processing workflows to 2.1 cm with the integrated approach — an improvement exceeding 50%. A single processing pass was sufficient for the relatively calm conditions of the test site, though iterative refinement may benefit more dynamic water surfaces. The presented methodology is generic and can be embedded in any laser scanning framework supporting modular georeferencing and refraction correction.

Gottfried Mandlburger, Lucas Dammert, Jan Rhomberg-Kauert et al. · 0 citations
Open access Jul 2026

Vertical Accuracy Assessment and Bias Correction of Freely Available Global DEMs

Accurate digital elevation models (DEMs) are essential for hydrological modelling and floodplain analysis, particularly in low-relief floodplains where small elevation errors can significantly affect flow routing and inundation extent. This study evaluated the vertical accuracy of six freely available global DEMs across the Flinders River catchment, North Queensland, Australia, using 30,916,100 quality-filtered ICESat-2 ATL06 elevation points for regression-based bias correction and airborne LiDAR datasets from five benchmark regions for independent validation. The evaluated DEMs included TANDEM-X, Copernicus DEM, ALOS AW3D30, SRTM, ASTER GDEM, and the Hydrological DEM. Vertical accuracy was assessed using mean error (ME), root mean square error (RMSE), and residual dispersion before and after calibration. Results showed substantial pre-calibration bias in the Hydrological DEM (ME = −2.93 m) and SRTM (ME = −2.66 m), whereas Copernicus DEM showed minimal initial bias (ME = −0.01 m). Regression-based correction reduced mean errors to within ±0.13 m across all DEMs. SRTM showed the largest improvement, with RMSE decreasing from 3.20 m to 0.55 m, while TANDEM-X achieved the highest post-calibration accuracy (RMSE = 0.14 m). Independent LiDAR validation confirmed improved vertical accuracy while preserving terrain morphology and river gradients.

L. Jafari, Ben Jarihani, J. Koci et al. · 0 citations
Review Open access Jul 2026

Assessment of Radial Distortion Parameter Variability in Airborne Photogrammetry: Implications for Atmospheric Refraction

Abstract. The Valpelline Valley, located in the northern Aosta Valley (Italy) along the Swiss border, is a typical Alpine valley shaped by glacial and fluvial processes. Characterized by a large altitudinal range (900-4000 m a.s.l.) and hosting glaciers feeding the Place Moulin reservoir, the area plays a key role in regional hydroelectric production. Since 2020, GlacierLAB has been conducting glacier monitoring activities through biannual aerial photogrammetric surveys, overcoming the logistical constraints imposed by the steep and inaccessible morphology of the valley.The surveys were performed using a medium-format camera mounted under an aircraft wing and equipped with GNSS and IMU systems. Due to the lack of synchronization between the camera shutter and GNSS receiver, georeferencing relied on Ground Control Points (GCPs), whose spatial distribution is often limited in high-mountain environments. This condition makes camera calibration a critical factor for ensuring reliable multi-temporal analysis.This study investigates the behavior of the radial distortion parameter k1 using images previously corrected for optical distortion. A multi-run bundle adjustment strategy was applied in Agisoft Metashape, including baseline configurations, global and image-wise estimation of k1, and robustness tests under different GCP setups. Statistical analyses reveal a systematic and significant dependence of k1 on the vertical camera–terrain distance.However, comparison with a theoretical atmospheric model based on the Saastamoinen formulation shows weak correlation, indicating that the observed effect cannot be attributed solely to atmospheric refraction. Instead, k1 acts as a compensatory parameter absorbing depth-dependent systematic effects related to block geometry and acquisition conditions.

M. Macelloni, N. Grasso, A. Cina · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.