Skip to content
Open access

[Translated article] Use of uncemented modular diaphyseal stems in salvage hip replacement after cut-out failure of cephalomedular fixation for extracapsular hip fractures. Monocentric series.

Oct 2026 · Revista Española de Cirugía Ortopédica y Traumatología · 0 citations
Medicine

TL;DR

Prosthetic salvage after cut-out with uncemented modular diaphyseal stems is a complex surgery with a significant risk of complications, especially dislocation and periprosthetic fracture.

Abstract

Background

AND

Objective

There are different treatments for cut-out failure after intramedullary nailing in hip fractures. Salvage with hip arthroplasty is an accepted method in frail elderly patients and in cases of articular cartilage damage or compromised bone stock precluding re-osteosynthesis. However, this is not without complications (10-66%) due to its complexity. MATERIAL AND

Methods

A single-center retrospective case series of patients treated with salvage arthroplasty using an uncemented modular diaphyseal fixation stem (Arcos® system, Zimmer Biomet). Minimum follow-up was 1 year.

Results

Fourteen cases were recorded, nine after Gamma3® nailing and five after Intertan® nailing. The posterolateral approach was the most commonly used (10 cases). Eight total hip replacements, three double mobility replacements, and six bipolar hemiarthroplasties were implanted. At 30 days, 92.9% were able to walk indoors with technical support. During the first year, six patients (42.8%) had complications related to the implant: three periprosthetic fractures, one acetabular erosion, and three dislocations. No patients died during hospitalization or at 30 days; one patient (7.1%) died within a year.

Discussion

AND

Conclusion

Prosthetic salvage after cut-out with uncemented modular diaphyseal stems is a complex surgery with a significant risk of complications, especially dislocation and periprosthetic fracture. These implants allow the deficient proximal areas to be by-passed and restore the length, version, and offset, making them a possible alternative in selected patients, although not without complications. EVIDENCE LEVEL Level IV.

Read PDF

Similar papers

Open access Nov 2026

Functional Outcomes of Primary Cemented Bipolar Hemiarthroplasty for Comminuted Intertrochanteric Femur Fractures in Elderly Patients: A Prospective Study

Abstract Introduction: Intertrochanteric fractures are among the most common fragility fractures in the elderly, and comminuted, unstable patterns are difficult to manage with fixation alone because of poor bone stock and loss of posteromedial support. While intramedullary devices, such as the proximal femoral nail rem...

A. KiranKumar, B. S. Vamshi, Bhushan Chickle · 0 citations
Review Open access Oct 2026

Treatment of Vancouver B2 and B3 Periprosthetic Femoral Fractures Using a Modular Tapered Stem: Survivorship and Radiographic Outcomes at Mean 7.8-Year Follow-Up.

INTRODUCTION Periprosthetic fractures (PPF) of the femur are a frequent complication following total hip arthroplasty (THA). Revision THA using a modular tapered stem is a common treatment strategy for these fractures. The purpose of this study was to report the survivorship and clinical outcomes of revision THA using...

F. Chaudhry, A. Bridger, Kunal Kolhatkar et al. · 0 citations
Open access Nov 2026

Functional Outcomes Following Cemented Bipolar Hemiarthroplasty Versus Total Hip Arthroplasty for Displaced Femoral Neck Fractures in Older Adults: A Retrospective Cohort Study

Background: Older persons frequently sustain femoral neck fractures, which are linked to significant morbidity and functional loss. Although total hip arthroplasty (THA) and cemented bipolar hemiarthroplasty (CBH) are common treatment choices, there is ongoing debate regarding which is better. Methodology: The Departme...

Shahzeena Kaleem, Hafiz Muhammad Jamal Fareed, Usama Nazir et al. · 0 citations
Open access Nov 2026

Multicenter retrospective study on the efficacy of reconstruction using a polished taper cemented stem for periprosthetic femoral fractures following total hip arthroplasty and hemiarthroplasty.

BACKGROUND Periprosthetic femoral fractures (PPF) after hip arthroplasty are serious, with high complication rates, poor outcomes, and increased mortality. Surgical options include osteosynthesis and revision arthroplasty, but optimal management remains controversial. This study aimed to evaluate postoperative clinical...

M. Kadowaki, Hiroshi Fujita, T. Iwase et al. · 0 citations
Review Open access Oct 2026

FP12.5 Long-Term Periprosthetic Fracture Risk After Hip Resurfacing Arthroplasty: A 25-Year Analysis Supporting Femoral Neck Preservation

Abstract ICLA12 - The Chondral Masterclass: Advanced Scaffolds, Orthobiologic Realities, and Young THA, Auditorium B (BMCC Level 1), October 9, 2026, 10:30 - 12:30 Introduction Femoral neck fracture (FNF) is the most common early failure mode in hip resurfacing arthroplasty (HRA). However, there are concerns that prese...

D. Gaillard-Campbell, T. Gross · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.