Skip to content

An experimentally calibrated nanodosimetry-based framework for predicting LET-dependent relative biological effectiveness in proton boron capture therapy

Oct 2026 · Physics in Medicine and Biology · Vol 71 · 0 citations
Medicine Physics

TL;DR

PBCT showed consistently higher RBE than proton therapy, with a greater advantage at higher LET, supporting future biological optimization of PBCT.

Abstract

Objective. Proton boron capture therapy (PBCT) studies focus on physical dose enhancement or biological observations, while quantitative prediction of biological effectiveness remains limited. This study aimed to establish a framework combining Monte Carlo (MC) simulation, nanodosimetry, and radiobiological experiments to evaluate the relative biological effectiveness (RBE) of PBCT. Approach. Geant4-based MC simulations and a pre-calculated nanodosimetric database were used to determine mixed-field nanodosimetric parameters, including M1, M2, and F2. Clonogenic survival experiments were performed using a clinical 70 MeV proton beam and a 6 MV photon beam. U-87 MG cells were irradiated with photons, protons, and PBCT at 0, 2, 4, 6, and 8 Gy using boronophenylalanine (BPA, 21.0 ppm 11B). Survival data were fitted with the linear–quadratic model, and the resulting α and β values were used to optimize the logistic nanodosimetry model (LNDM) for depth-dependent RBE prediction. Main results. The LNDM, combined with MC-derived nanodosimetric parameters and experimental survival data, reproduced the measured radiobiological response with differences in α and β below 0.5% at the experimental cell position, corresponding to a water-equivalent depth of 3.9 cm and located on the rising edge of the Bragg peak. PBCT consistently exhibited higher α and RBE values than proton irradiation across the investigated linear energy transfer (LET) range. At 3.9 cm, PBCT increased RBE by 8.7% compared with protons. For the 70 MeV beam, PBCT yielded α = 0.116 Gy−1, β = 0.023 Gy−2, and RBE = 1.25, compared with α = 0.076 Gy−1, β = 0.023 Gy−2, and RBE = 1.15 for proton therapy. Significance. An experimentally calibrated framework integrating MC simulation, nanodosimetry, radiobiological experiments, and the LNDM was established for LET-dependent PBCT RBE prediction based on biological calibration data. PBCT showed consistently higher RBE than proton therapy, with a greater advantage at higher LET, supporting future biological optimization of PBCT.

View source

Similar papers

Oct 2026

Cytogenetic biodosimetry for radiotherapy: anthropomorphic phantom-based dose-response calibration and in vivo evaluation.

OBJECTIVES Cytogenetic biodosimetry has limited applicability in radiobiological monitoring of radiotherapy due to methodological constraints. To address this problem, we developed and evaluated an inverse biodosimetry approach that included cytogenetic dose-response curve (DRC) construction using an anthropomorphic ti...

Volodymyr Vinnikov, Lucián Zastko, Anita Klačková et al. · 0 citations
Oct 2026

A Clinical Dose Prescription System for Proton Radiotherapy Based on the Mayo Clinic Florida Microdosimetric Kinetic Model.

PURPOSE Clinical proton dose prescription uses a fixed relative biological effectiveness (RBE) factor of 1.1 despite preclinical and clinical evidence that RBE varies with dose, radiation quality, and tissue radiosensitivity, particularly near the distal edge of treatments. We present a proton clinical dose-prescriptio...

A. Parisi, K. Furutani, S. Hartzell et al. · 1 citation
Open access Sep 2026

Effectiveness of double-layer beam shaping assembly neutron beam for boron neutron capture therapy: A microdosimetric study using particle and heavy ion transport code system

Boron neutron capture therapy (BNCT) is a cancer therapy currently under development. The key to successful BNCT therapy depends on the ability of 10B to be distributed within cells and the quality of the neutrons being used. The research aims to study the effectiveness of the neutron beam from Double-Layer Beam Shapin...

Bilalodin Bilalodin, F. Abdullatif, P. Lestari et al. · 0 citations
Review Open access Oct 2026

Review on carbon ion minibeam radiotherapy: Dosimetry, dynamic phantoms and radiobiology.

Carbon ion minibeam radiotherapy (CIMRT) is an emerging technique that intends to combine the biological and physical advantages of carbon ions with the normal-tissue sparing potential of spatially fractionated dose delivery. The increased linear energy transfer (LET) and higher relative biological effectiveness (RBE)...

C. Stengl, J. Vedelago, O. Jäkel · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.