Skip to content

A-402 A total internal reflection fluorescence smartphone-based imaging platform toward point-of-care diagnostic testing

Oct 2026 · Clinical Chemistry · 0 citations

Abstract

Smartphones (SPs) are being explored for point-of-care testing (POCT) due to their global ubiquity, user-friendliness, portability and on-board technologies. The SP camera, although not designed and optimized for the purpose, can be used for analytical measurements and biological imaging when paired with advanced luminescent materials like quantum dots (QDs). In addition, with some clever engineering and the attachment of dongles or other small optics, SP cameras can have sufficient sensitivity to be a viable alternative to sophisticated laboratory instruments for the quantitative detection of biomarkers. To this end, we have developed and benchmarked a total internal reflection fluorescence smartphone imaging platform (TIRF)-SIP. The TIRF method only excites fluorophores bound to the surface of a glass slide, greatly reducing interfering background autofluorescence from biological sample (e.g. serum, urine). It also eliminates the need for washing steps in an assay and enables real-time detection. This elimination of sample preparation steps and signal development steps are ideal for POCT. Although TIRF has been proposed for POCTs previously, it has generally utilized a lab-based TIRF microscope that is incompatible with true POCT. A smartphone-based TIRF device would be globally accessible, including in rural, remote, and low-resource settings. The TIRF-SIP is composed of 3D-printed parts, simple optics, and a low-cost laser diode. The device contains a dove-prism that TIRs the laser into the sample slide. The analytical performance of this device was evaluated using fluorescent materials in a mock assay with dextran-coated QDs (Dex-QDs) and a slide-immobilized Concanavalin A (ConA) lectin that binds to dextran. Advanced made-for-purpose materials like super-QD assemblies were also evaluated in this assay. Proof-of-concept immobilization assays were also conducted in unprocessed biofluid samples including urine and plasma, and sandwich immunoassay development is ongoing. For each material, the trend in the smartphone-measured PL intensity versus concentration was approximately sigmoidal, with a dynamic range of at least one order of magnitude. For 10 µL aliquots of QDs and super-QD assemblies, the limits of detection (LODs) were 1 nM and 1 pM, respectively. When comparing TIRF to conventional epi-illumination, the TIRF displayed substantial background reduction with unprocessed biofluids. The sandwich immunoassay also shows promising selectivity and sensitivity. This research is a step toward improving molecular diagnostic capability and accessibility in resource-limited settings, such as rural and remote communities in Canada and worldwide. In addressing the capability gap between these communities and urban centers, this technology supports greater equity and inclusion in modern health care.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.