Non-ionising optical tomography offers a safer alternative to traditional imaging techniques for radiation-sensitive biological and, particularly, human tissues. In this study, we developed a laser scanning system incorporating axial, transverse, and rotational motion to acquire projection data from optically heterogeneous phantom media. A 632.8 nm laser was used to illuminate targets embedded within water, clear gelatin, red gelatin and green gelatin to provide phantom media with differing optical attenuation properties. By capturing transmitted and forward-scattered light with a camera detector and constructing sinograms, we applied the inverse Radon transform to reconstruct cross-sectional images of the embedded targets. The results demonstrate recovery of spatial information from inclusions in relatively low-scattering phantom media, while reconstruction quality progressively deteriorates as optical attenuation and path length increase. Comparison with reported breast-tissue optical properties shows that the present phantoms represent a substantially lower-scattering regime and should not be considered quantitative tissue-equivalent models. The study therefore provides a proof-of-concept evaluation of the acquisition and reconstruction framework, while identifying the limitations that must be addressed before extension to strongly diffusive, biologically relevant optical conditions.
Ultrasound computed tomography (USCT) has emerged as a promising multi-modal imaging technique, yet standardized phantoms for validating its reflection-mode performance remain lacking, hindering system calibration and cross-platform comparison. In this study, we designed and fabricated a suite of agar-based tissue-mimi...
Zhao-Hui Liu, Di Zhang, M. Yuchi et al.· Bioengineering· 0 citations
X-ray ghost imaging has emerged as a promising computational imaging modality capable of forming images from spatially integrated measurements. Unlike optical implementations, image formation is governed by multiple energy-dependent photon-matter interactions: photoelectric absorption, Compton scattering, and fluoresce...
R. H. Shukrun, A. Ben Yehuda, Y. Korotinsky et al.· 0 citations
Medical spectral imaging can not only show the geometric shapes of biological tissues, but also reveal their chemical and physical characteristics, making it a powerful tool for medical diagnosis. Although existing multispectral and hyperspectral imaging techniques can provide detailed biochemical and biophysical data,...
Acoustic shadows from bone and other highly attenuating tissues obscure clinically important structures in ultrasound. In fetal brain imaging, skull-induced artefacts disproportionately degrade the hemisphere closer to the transducer (proximal), limiting symmetric assessment of the two hemispheres. Existing correction...
Valentin Bacher, Pak-Hei Yeung, Bernhard Kainz et al.· arXiv.org· 0 citations
Ultrasound imaging has been extensively employed in biomedical diagnosis and clinical research, owing to its compelling merits of non-ionizing radiation, cost-effectiveness, and real-time visualization. However, conventional ultrasound imaging systems are fundamentally constrained by diffraction-limited spatial resolut...
Jia-Jie He, Jun-Hao Jiang, Hai-Jun Luo et al.· Chinese Physics B· 0 citations
High-resolution two-dimensional dosimetry is important for radiotherapy quality assurance. Scintillating fiber tomodosimetry is attractive because of its near water equivalence and fine spatial sampling, but most implementations rely on detector rotation. Here, we report Monte Carlo simulations of a static multi-stack...