Assessment of sequential distalization with aligners using cone-beam computed tomography merged with intraoral scans.
Abstract
INTRODUCTION Sequential distalization with clear aligners, supplemented by Class II elastics, is commonly used to treat mild-to-moderate Class II malocclusions. Although favorable clinical outcomes have been reported, the underlying mechanism of tooth movement remains incompletely understood because of the methodologic limitations of conventional analyses.
Methods
This retrospective study included 30 adults treated with Invisalign sequential distalization combined with Class II elastics. Pretreatment and posttreatment cone-beam computed tomography images and intraoral scans were merged using segmentation and registration software. The fused models were superimposed on stable maxillary structures with computer-aided design/computer-aided manufacturing software, and the movement of the maxillary first molars was quantified in 3 planes of space using a 3-dimensional coordinate system.
Results
The mesiobuccal cusp tip of the maxillary first molar moved distally by a mean of 1.75 mm, whereas the mesiobuccal root apex moved distally by only 0.35 mm, representing 69.7% and 27.6% of the planned movement, respectively. The achieved distal crown tipping (7.14°) significantly exceeded the planned value, whereas the mesial-out rotation (8.22°) was only slightly greater than planned.
Conclusions
In patients treated with sequential distalization and Class II elastics, maxillary first molar distalization occurred primarily through distal crown tipping and mesial-out rotation. Cone-beam computed tomography- intraoral scan fused models enabled precise 3-dimensional assessments of these tooth movements.