TL;DR

Although muscle normalization is proposed to reduce scanner variability, it did not improve predictive performance in this cohort and occasionally reduced reproducibility, and there is an urgent need for more standardized, robust imaging biomarkers.

Abstract

MRI is increasingly used to assess treatment response in muscle-invasive bladder cancer (MIBC), but only qualitatively. This study evaluates the reproducibility and predictive value of quantitative apparent diffusion coefficient (ADC), thought to be a non-invasive surrogate for tumor cell density, in patients with MIBC receiving neoadjuvant immunotherapy. MRI data from 35 patients, enrolled in the Phase-Ib NABUCCO trial, were analyzed. ADC maps were derived from pre- and post-treatment MRI scans. Three independent radiologists assessed multiple regions of interest (ROIs) to evaluate inter-observer agreement and predictive performance for pathological complete response (pCR). ADC values were normalized using muscle tissue as a reference. Additionally, we analyzed the correlation between ADC and cell densities, derived from multiplex immunofluorescence (mIF) data. ADC measurements from the whole-tumor ROI (n = 25) demonstrated the highest reproducibility (0.98, 95% CI = [0.95–0.99]), but lacked predictive value (AUC = 0.31, 95% CI = [0.12–0.53], p = 0.109). The most hypointense ROI (n = 22) showed the strongest predictive value for pCR (AUC = 0.80, 95% CI = [0.57–1], p = 0.025), though with limited reproducibility. The difference between baseline and follow-up ADC values in the hypointense region (n = 20) again showed the highest diagnostic accuracy (AUC = 0.80, 95% CI = [0.58–0.98], p = 0.015). Although muscle normalization is proposed to reduce scanner variability, it did not improve predictive performance in this cohort and occasionally reduced reproducibility. No significant correlation was found between whole-tumor ADC and cell density. Despite analyzing different measurement techniques for ADC values, none was simultaneously reproducible and predictive, nor provided insights into the biology of the tumor. While ADC shows promise in MIBC, there is an urgent need for more standardized, robust imaging biomarkers. Question Non-invasive biomarkers are urgently needed to guide bladder-preserving strategies in MIBC. Findings DWI-MRI shows promise, but standardized robust imaging biomarkers are essential for reliable response assessment. Critical relevance statement Standardized or AI-assisted ROI segmentation could improve ADC reproducibility and diagnostic accuracy in multicenter studies.

Read PDF

Similar papers

Open access Oct 2026

Slow Diffusion Coefficient Derived from High b -Value Diffusion-Weighted MRI for Assessing Pathological Complete Response after Neoadjuvant Chemotherapy in Breast Cancer: An Exploratory Machine Learning Analysis

Background The apparent diffusion coefficient (ADC) is used to assess breast cancer response but may be influenced by perfusion and T2-related effects. Aim The aim of the study was to compare ADC-only, slow diffusion coefficient (SDC)-only, and combined ADC–SDC models and to evaluate whether SDC provides information co...

K. Sakoda, S. Baba · 0 citations
Open access Oct 2026

Predicting Pathologic Complete Response in Breast Cancer Using Pre-Treatment DCE-MRI

Prediction of pathological complete response (pCR) in breast cancer is relevant for clinical decision making and individual risk assessment, but remains challenging at present. This study aimed to design and validate clinically-informed, interpretable dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) frame...

B. N. Prathibha, Rashmi P. Karchi · 0 citations
Open access 2025

Predictive value of nomogram-based multiparametric MRI combined with pathological biomarkers for HIF-1α Expression in Breast Cancer

Background Hypoxia-inducible factor-1 α (HIF-1 α ) expression is associated with tumor progression, metastasis, and therapeutic resistance in breast cancer; however, its non-invasive prediction remains challenging. The aim of this study was to evaluate the predictive value of clinicopathological characteristics, conven...

Wei-Wei Wang, Fan Zhao, Ya-Han Zhong et al. · 0 citations
Open access Oct 2026

Negative Correlation Between ADC Values and GPC3 Expression in Hepatocellular Carcinoma: A Quantitative Diffusion-Weighted Imaging Study

Objective To investigate the association between apparent diffusion coefficient (ADC) derived from diffusion-weighted imaging (DWI) and glypican-3 (GPC3) expression in hepatocellular carcinoma (HCC), and to explore the potential of ADC as a non-invasive imaging biomarker for assessing GPC3 expression Methods This retro...

Zhao-Ing Fu, Yong-Tan Huang, Ying Liu et al. · 0 citations
Oct 2026

Imaging-based strategies to optimize preoperative evaluation in invasive lobular Carcinoma: Impact of delayed-phase MRI and modified US thresholds for lymph nodes.

OBJECTIVE To investigate whether delayed-phase dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) improves MRI-histopathology size agreement and whether modifying the ultrasonographic cortical thickness threshold improves diagnosis of axillary lymph node metastasis in invasive lobular carcinoma (ILC) compar...

Meesun Lee, Heera Yoen, Jiwon Koh et al. · 0 citations
Oct 2026

Diagnostic Performance of PI-RADS v2.1, PSA Density, and ADC in Predicting Clinically Significant Prostate Cancer with Histopathological Correlation.

INTRODUCTION/BACKGROUND Multiparametric magnetic resonance imaging (mpMRI) plays a central role in prostate cancer detection. The Prostate Imaging Reporting and Data System version 2.1 (PI-RADS v2.1) improves risk stratification; however, the additional value of combining PI-RADS with prostate-specific antigen density...

G. Tonkaz, Ahmet Aktan · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.