Rectal cancer radiotherapy quality improvement: Implementation in an LMIC setting.
Abstract
590 Background: The Veterans Affairs and American Society for Radiation Oncology (VA-ASTRO) published consensus-based quality indicators (2022), which were reviewed and adapted by the Quality Audit for Radiotherapy in Rectal Cancer group (QUARRC) of the Gastro-Intestinal Oncology Society (GIOS), India, for applicability in LMIC settings. We report institutional implementation of these quality metrics and lessons learned from a structured quality improvement (QI) initiative in a government-funded, academic, tertiary cancer centre in India. Methods: 50 consecutive rectal cancer patients receiving curative-intent radiotherapy (Jan–June 2025) were audited against 45 VA-ASTRO/QUARRC metrics (40 documentation, 5 timeline). Metrics below benchmark were reviewed by the departmental group for QI selection (Delphi ≥70% agreement). Classical A3 QI tools (SMART goal, process mapping, Gemba walk, 5 Whys, fishbone and Pareto) were used to identify key drivers and interventions, implemented through Plan–Do–Study–Act (PDSA) cycles. Progress and sustainability were monitored using run charts. Results: Thirty of 45 metrics (66.7%) met benchmark (29/40, 72.5% documentation; 1/5, 20% timeline). 12/15 unmet metrics were selected for QI (except vaginal stenosis counselling and diagnosis-to-treatment and surgery timelines). Following two predefined PDSA cycles, all selected metrics achieved thresholds and were sustained over 6 months. Major barriers for documentational matrices (Table 1) were missing items in current templates, which were modified. For timeline-based thresholds (MDT to RT start and simulation to RT start), absence of real-time monitoring during various substeps of the radiation process was a major barrier, for which an Excel-based auto prediction model was created showing expected dates with colour-coded delay warnings. Both barriers further required continued education, training and sensitization for implementation. Synoptic documentation and timeline-based RT process monitoring screens are being developed within existing indigenous software (EMR and ROIS) by the hospital IT team, as commercial solutions with customization and integration are not cost-effective. Conclusions: Both Western and LMIC-appropriate QI metrics were successfully implemented. Development of low-cost indigenous software is essential to sustain these quality improvements in LMIC settings. Multicentric validation is ongoing. Documentation quality metrics. Measure QUARRC Benchmark ASTRO Benchmark Baseline Post-QI Smoking status 90% 90% 44% 100% Smoking cessation counselling/referral 80% 80% 0% 100% Pregnancy screening 100% 100% 0% 100% Prior radiation 100% 100% 0% 100% Family history 100% 100% 26% 100% Fertility counselling 100% 100% 16% 100% Cardiac device screening 100% 100% 0% 100% Clinical trial enrolment NA NA 18% 100% MMR/MSI status NA NA 58% 100% Baseline pain assessment with plan 90% 90% 10% 100%