Skip to content
Open access

Evaluation of Acute Electrical and Hemodynamic Improvement During Left Bundle-Branch Area Pacing Modalities for Resynchronization Therapy.

Oct 2026 · Journal of the American Heart Association : Cardiovascular and Cerebrovascular Disease · pp. e049208 · 0 citations · 23 references
Medicine

TL;DR

Selective LBB pacing yields the greatest acute hemodynamic benefit, and the hemodynamic-optimal atrioventricular interval is shorter than the electrical-optimal atrioventricular interval, suggesting that modest atrioventricular interval shortening after electrical optimization may better maximize hemodynamics.

Abstract

Background

While cardiac resynchronization therapy is effective in dyssynchronous heart failure, suboptimal response remains frequent. The acute hemodynamic profile of different left bundle-branch (LBB) area pacing modalities is poorly defined. Moreover, atrioventricular optimization guided by QRS duration (QRSd) may not yield the greatest hemodynamic benefit.

Methods

Twenty-four patients with heart failure, reduced ejection fraction, and LBB block underwent sequential testing of right ventricular septal pacing, left ventricular septal pacing, nonselective LBB pacing, and selective LBB pacing during cardiac resynchronization therapy implantation in a prospective, within-subject physiological study. At each modality, electrical end points were QRSd and vectorcardiographic QRS area; hemodynamics were assessed with beat-to-beat systolic blood pressure (SBP). The atrioventricular interval producing maximal SBP improvement was compared with that producing the narrowest QRSd.

Results

LBB area pacing modalities significantly reduced QRSd, compared with right ventricular septal pacing (nonselective LBB pacing, 114.0±16.8 milliseconds; selective LBB pacing, 118.4±14.1 milliseconds; left ventricular septal pacing, 124.6±16.0 milliseconds; right ventricular septal pacing, 144.4±27.6 milliseconds; all P<0.01). At the atrioventricular interval that produced maximized SBP improvement, QRSd remained narrower with LBB area pacing than right ventricular septal pacing, and selective LBB pacing provided the greatest hemodynamic improvement (ΔSBP 16.3±5.2 mm Hg), exceeding left ventricular septal pacing (13.5±6.2 mm Hg) and nonselective LBB pacing (12.8±6.3 mm Hg; all P<0.05). Across modalities, the atrioventricular interval that maximized ΔSBP was consistently shorter than that minimizing QRSd (mean difference, 18-29 milliseconds).

Conclusions

Selective LBB pacing yields the greatest acute hemodynamic benefit, and the hemodynamic-optimal atrioventricular interval is shorter than the electrical-optimal atrioventricular interval, suggesting that modest atrioventricular interval shortening after electrical optimization may better maximize hemodynamics. REGISTRATION URL: https://www.clinicaltrials.gov; Unique Identifier: NCT07032064.

Read PDF

Similar papers

Open access Oct 2026

Left bundle branch area pacing in patients with heart failure and left bundle branch block leads to marked left ventricular reverse remodeling and regression of ventricular dyssynchrony

Conduction system pacing has emerged as a novel alternative to conventional biventricular pacing in patients with heart failure requiring cardiac resynchronization therapy (CRT). The aim of this study was to evaluate the rate of response and the degree of ventricular dyssynchrony in patients undergoing CRT...

J. Mizner, T. Knize, L. Povišer et al. · 0 citations
Oct 2026

Left bundle branch pacing vs left ventricular septal pacing in the same patients with heart failure and left bundle branch block.

Both LBBP and LVSP significantly improved left ventricular hemodynamics and mechanical synchrony without compromising RV function in the same patients undergoing CRTP, and LBBP potentially has superior left ventricular hemodynamic effects to LVSP.

Xin-Yi Huang, Shu-Fen Huang, X. Chen et al. · 0 citations
Review Open access Sep 2026

Left Bundle Branch Area Pacing: Current Clinical Practice and Future Perspectives.

Conventional right ventricular pacing (RVP) is associated with electromechanical dyssynchrony and may contribute to pacing-induced cardiomyopathy (PICM). Left bundle branch area pacing (LBBAP) has emerged as a physiological pacing strategy that engages the native conduction system. This review summarizes the current cl...

G. Leventopoulos, R. Koros, M. Derndorfer et al. · 0 citations
Open access Oct 2026

Clinical outcomes of left bundle branch pacing, left ventricular septal pacing, and deep septal pacing in bradycardia: a real-world cohort study

Left bundle branch area pacing (LBBAP) is increasingly adopted for bradyarrhythmias due to stable pacing thresholds and potential prevention of pacing-induced cardiomyopathy. However, the clinical impact of its subtypes, namely left bundle branch pacing (LBBP) versus left ventricular septal pacing (LVSP), remains...

H. Kono, N. Oyanagi, H. Chinen et al. · 0 citations
Open access Oct 2026

Left Bundle-Branch Area Pacing vs Right Ventricular Pacing for Atrioventricular Block and Preserved Left Ventricular Function: The LEAP-Block Randomized Clinical Trial.

Importance For patients with atrioventricular block requiring high-burden ventricular pacing, the optimal pacing strategy to reduce heart failure (HF) and all-cause mortality remains uncertain. Robust comparative evidence on the clinical outcomes of left bundle-branch area pacing (LBBAP) vs right ventricular pacing (RV...

Xiao-Fei Li, Hai-Xiong Wang, Wen-Juan Zhang et al. · 0 citations
Nov 2026

Preoperative high-frequency QRS parameters and left bundle branch area pacing response in non-ischemic left bundle branch block patients: An exploratory study.

BACKGROUND Left bundle branch area pacing (LBBP) has become a preferred as a novel strategy for cardiac resynchronization therapy (CRT). High-frequency QRS (HFQRS) analysis can detect subtle ventricular depolarization abnormalities that are not identifiable on standard electrocardiography and may provide novel markers...

Zhi-Hui Hou, Zhong-Wei Jiang, Xian-Kai Xia et al. · 0 citations