Biomechanical Design, Additive Manufacturing, and Proof-of-Concept Evaluation of a 3D-Printed Transradial Prosthesis with a Manual Ratchet-Type Locking Mechanism
Oct 2026· Biomechanics· Vol 6, pp. 94· 0 citations· 14 references
TL;DR
The manual ratchet mechanism provides an ultra-lightweight (344 g) and affordable (~$50 USD) assistive alternative, however, manual contralateral actuation occupies the sound hand (100% involvement during adjustment), precluding true bimanual independence.
Abstract
Background/Objectives: Upper-limb loss represents a critical clinical and socioeconomic challenge globally. While myoelectric devices offer multi-articulated grasping, their high cost restricts access in low-resource settings. This work presents the preliminary biomechanical design, Fused Deposition Modeling (FDM) manufacturing, and proof-of-concept evaluation of a custom transradial prosthesis (EVA) with a manual, incremental ratchet-type tensioning mechanism. Methods: Virtual CAD assembly was parametrically customized from user anthropometry. Finite Element Analysis (FEA) incorporating transversely isotropic material models (E_x = E_y = 2150 MPa, E_z = 1620 MPa) and transient dynamic impact simulations evaluated structural stresses and contact transitions. Physical prototypes were FDM-printed in Polyethylene Terephthalate Glycol (PETG) and Thermoplastic Polyurethane (TPU). Grip forces were experimentally measured using piezoresistive sensors, while transmission torque (M_knob = 1.37 N·m) was analytically derived. Ratchet reliability was tested over 1000 continuous cycles, and an able-bodied simulator pilot study (N = 5) evaluated usability (Box and Block Test, Donning/Doffing, System Usability Scale). Results: Peak static von Mises stress (45.0 MPa) remained below the PETG yield limit (47–60 MPa), whereas transient impact stress reached 53.8 MPa. Safe grip thresholds without slippage were established up to 5.3 kg for wood, 3.4 kg for iron, and 2.1 kg for glass. Experimental grip force measured 122.5 ± 4.2 N. Failure at 7.5 kg followed a two-stage sequence: hinge micro-delamination (6.5 kg) followed by internal return spring snapping. Cyclic ratchet testing showed 0.08 mm pawl wear and 0.2–0.4 mm back-slip with 90.9% retained grip force. Simulator testing yielded a Box and Block score of 14.2 ± 1.8 blocks/min, donning time of 28.5 ± 4.2 s, and a SUS score of 78.5/100. Conclusions: The manual ratchet mechanism provides an ultra-lightweight (344 g) and affordable (~$50 USD) assistive alternative. However, manual contralateral actuation occupies the sound hand (100% involvement during adjustment), precluding true bimanual independence. Near-term mitigations, including shoulder-driven pull-cables and sEMG solenoids, are proposed.
INTRODUCTION
Conventional wrist splints for carpal tunnel syndrome (CTS) may have limited anatomical fit and ventilation. This study developed and mechanically evaluated an anatomy-matched, 3D-printed wrist splint using stress-guided Voronoi lattice optimisation.
MATERIALS AND METHODS
Wrist and forearm geometry from...
De-Si Wang· Computer Methods in Biomecha...· 0 citations
This paper details the design, fabrication, and evaluation of three innovative mechatronic systems for simulating lower limb joint motion, with a focus on the hip, knee, and ankle, using 3D printing and advanced control techniques. Fabricated using CATIA V5 designs and Fused Deposition Modelling (FDM) technology, the m...
D. Prisecaru, D. Besnea, Florin Istudor et al.· Romanian Journal of Informat...· 0 citations
[Rheumatoid arthritis (RA) progressively impairs hand mobility and limits daily activities, and commercial orthoses are often rigid, poorly fitted, or costly. Previous work proposed a customized monomaterial thermoplastic polyurethane (TPU) exoesqueleton with a functional stiffness gradient and validated its geometry c...
Héctor Luis Gutiérrez Martínez, Enrique de Jesús Mohedano Torres, C. La Torre et al.· International journal of res...· 0 citations
Background: The prosthetic socket is the primary component responsible for comfort, stability, and load transfer in lower limb prostheses. Traditional transtibial socket fabrication relies on plaster casting and manual rectification performed by prosthetists, producing workflows that depend heavily on clinical experien...
Juan Sebastián Salgado Manrique, Laura Cuestas-Valenzuela, Christian Cifuentes-De la Portilla· Prosthesis· 0 citations
Passive prosthetic knee joints remain an attractive solution for transfemoral amputees in low-resource settings because of their low cost, mechanical simplicity, and ease of maintenance. But there are numerous commercial designs which are either relatively heavy or mechanically complex. In this work, the design, fini...
F. M. Kadhim, Mais Al-Saffar, N. Sadek et al.· International Review of Appl...· 0 citations
The Ertty Gap III appliance has been proposed for the orthopaedic treatment of growing patients with skeletal Class III malocclusion. This study aimed to characterise its modelled mechanical response under a hypothetical force-controlled loading configuration, rather than to reproduce clinical screw activation. A three...