Measurement Uncertainty in Vital Sign Detection with Frequency-Comb Continuous-Wave Radar on Unmanned Aerial Vehicles
Abstract
Radar-based vital sign detection enables contactless respiration monitoring and is a promising approach for search-and-rescue operations. Although radar self-motion artifacts are known to significantly degrade detection performance, the associated uncertainty characteristics under UAV deployment remain insufficiently understood. In this contribution, measurements using a frequency-comb continuous-wave radar and a mechanically actuated breathing dummy are conducted to evaluate frequency estimation under varying conditions, including obstructions and UAV motion. Respiration frequency is estimated using spectral and time-frequency methods, and uncertainty is quantified within a variance-based framework. Results show accurate estimation under stationary or line-of-sight conditions, whereas uncompensated UAV motion and radar-target distance increase uncertainty and reduce spectral peak stability, establishing a baseline for evaluating motion compensation strategies.