Skip to content
Review

A-131 HbA1c Result Patterns by Capillary Electrophoresis in Primary-Use and Reference-Use Laboratory Populations

Oct 2026 · Clinical Chemistry · 0 citations

Abstract

Hemoglobin A1c (HbA1c) represents average glycemia over ∼2–3 months based on glycation of HbA. Capillary electrophoresis (CE) separates Hb fractions based on charge and produces electropherograms that allow for integrated flags and interpretive comments when interferences or Hb variants are detected. ARUP Laboratories supports University of Utah Health sites for first-line testing as well as reference testing for various health care systems across the US. This study describes CE HbA1c result patterns for a primary-use population (UU), a reference-use population within Utah (RP-U), and reference-use population outside of Utah (RP-E). Retrospective review was performed on more than half million HbA1c results analyzed by CE. Flagged results were classified into five categories. One category represented conditions in which CE could still report an accurate HbA1c result: 1) Hb variant detected in a heterozygous individual. Four categories represented conditions in which CE could not report an accurate HbA1c result: 2) HbA1c <4%; 3) absence of HbA; 4) HbA1c not calculated due to assay interference; and 5) HbF >23%. Result flag patterns and frequencies for all test results and cohorts were assessed. Comparative analysis was conducted between each cohort to determine differences between reference-use and primary-use populations, including by-state evaluation. Analyses specific to the Utah population include evaluation of flagged results by geographic region for primary-use groups and result distributions and pattern comparisons between UU and RP-U groups. CE delivered reliable performance in both UU and RP populations. Approximately 5% of all tests were flagged for one of the five categories, however, 98.24% of samples yielded a reportable HbA1c as most heterozygous variants do not interfere with accurate HbA1c quantitation. For groups UU and RP (RP-U + RP-E), the percent of non-reportable results were 0.065% and 2.38% where HbA1c?23%, and 0.020% and 0.91% had unresolvable interferences, respectively. In evaluating the RP-E group by state, HbF >23%, heterozygous-, and homozygous Hb variant rates were highest at 8.86%, 57.25% and 14.99%, with medians of 0.31%, 11.50% and 13.49%, respectively. For the UU population, the percent of flagged samples was substantially lower than that of RP-U and RP-E groups. Furthermore, mean HbA1c differences were significant between UU samples at 5.86% and RP-E samples at 7.02% (p <0.0001). HbA1c distributions between UU and RP-E groups are markedly different where the UU dataset is unimodal with minimal skew and the RP-E distribution is multimodal with positive skew of the primary distribution. Results from this study highlight the benefits of the use of CE in reference-use and primary-use groups including the ability to detect undiagnosed hemoglobinopathy across populations, supporting equitable testing; effective detection of interfering hemoglobin variants while providing valid HbA1c results for most samples with heterozygous variants; and increased confidence in verifying very low results. However, this study also highlights the limited number of primary-use patients that would benefit from a uniform CE workflow and supports a workflow of primary-use testing by immunoassay or enzymatic method with selective testing by CE to balance operational effectiveness while maintaining test equity.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.