Contact Pressure-Based Modeling and Experimental Force Characterization of Twisted Elastic Actuators (TEAs)
Abstract
Twisted String Actuators (TSAs) use inextensible filaments, making them inherently position output devices with limited force resolution and no capacity for passive re-extension. Replacing the inextensible strands with elastomeric filaments produces Twisted Elastic Actuators (TEAs): a class of compliant tendon actuators in which the elastic material simultaneously serves as the transmission element and a distributed spring, shifting the device toward force output behavior analogous to series elastic actuators. Here, we present an analytical model for TEA force generation that extends the classical helix-based TSA formulation by incorporating contact-pressure-driven radial stresses and the resulting Poisson-induced axial relaxation, thereby accounting for material effects not covered in prior TSA models. The model is validated experimentally across three actuator configurations (2-string 1.75 mm, 2-string 3.00 mm, and 3-string 1.75 mm TPU 85 A filaments), achieving a maximum mean absolute percentage error of 8.3% across all configurations within the pre-peak elastic regime. Hysteresis measurements over 20 actuation cycles confirm a hysteresis ratio of 1.48%, indicating limited energy dissipation and strong elastic recovery during cyclic actuation.