The Effects of Preservation and Structural Rhinoplasty on Voice Parameters.
Abstract
Objectives
To compare acoustic voice changes after preservation and structural rhinoplasty in women undergoing surgery for aesthetic indications. STUDY
Design
Retrospective comparative study with repeated pre- and postoperative measurements.
Methods
Forty women aged 20-30 years underwent preservation rhinoplasty (n = 20) or structural rhinoplasty with spreader graft reconstruction (n = 20). No preoperative nasal obstruction or laryngeal pathology was detected. Archived sustained /a/ recordings from one week preoperatively and 3 months postoperatively were analyzed in Praat for fundamental frequency (fo), local jitter, local shimmer, and harmonic-to-noise ratio (HNR). Smoothed cepstral peak prominence (CPPS) was added as an exploratory outcome. Within-group changes and between-group change scores were compared.
Results
In the preservation group, fo remained stable (214.26 ± 8.97 vs 213.93 ± 8.90 Hz; P = 0.220), whereas jitter decreased from 0.327 ± 0.066% to 0.281 ± 0.065%, shimmer decreased from 2.05 ± 0.35% to 1.85 ± 0.36%, and HNR increased from 24.91 ± 1.48 to 26.19 ± 1.43 dB (all P < 0.001). In the structural group, fo also remained stable (220.29 ± 11.16 vs 220.29 ± 11.50 Hz; P = 0.985), while jitter decreased from 0.342 ± 0.086% to 0.304 ± 0.084%, shimmer decreased from 1.99 ± 0.37% to 1.82 ± 0.38%, and HNR increased from 24.66 ± 1.37 to 25.86 ± 1.49 dB (all P < 0.001). CPPS did not change significantly: preservation, 16.31 ± 1.20 vs 16.24 ± 1.41 dB (P = 0.543); structural, 17.65 ± 1.15 vs 17.54 ± 1.35 dB (P = 0.337). Preoperative CPPS was higher in the structural group (P < 0.001). The jitter reduction was greater with preservation (-0.046 ± 0.012% vs -0.038 ± 0.011%; P = 0.032). Changes in fo (P = 0.383), shimmer (P = 0.096), HNR (P = 0.457), and CPPS (P = 0.826) did not differ significantly between groups.
Conclusion
Both techniques were associated with changes in perturbation and HNR, with no significant CPPS change. The small isolated jitter difference remains exploratory; the findings do not establish overall voice quality improvement or superiority of either technique.