Three-Dimensional Electromagnetic Performance Investigation of a Hybrid Stepper Motor
Abstract
A three-dimensional (3D) transient finite element analysis (FEA) model of a hybrid stepper motor (HSM) is established to evaluate the stator and rotor tooth fields, windings, axially magnetized permanent magnets (PMs), and rotor motion within a common numerical framework. At 450 rpm and approximately 2 A rms per phase, the model is used to obtain the zero-current cogging torque, energized phase terminal voltage, and core loss. Three commercial SmCo PM grades are then compared under unchanged geometry, excitation, motion, meshing, and post-processing conditions. Relative to XGS208, XGS191/160 reduces the peak-to-peak cogging torque by 4.25% but increases the mean rms phase voltage and total core loss by 5.84% and 7.51%, respectively. XGS223/160 changes the cogging torque by only +0.36% while reducing the mean rms phase voltage and total core loss by 3.07% and 3.96%, respectively. Because cogging torque contributes to passive tooth alignment and holding, it is not intrinsically detrimental; PM selection should balance positioning requirements against voltage and loss. The 3D FEA model therefore provides a consistent basis for coordinated HSM performance assessment.