The implementation of the orthogonal detector arrays for patient specific QA in tomotherapy

Abstract

Helical Tomotherapy modulated the radiation beams intensity using binary multileaf movement synchronization with couch translation and gantry rotation. This complexity of delivery required a valid patient-specific quality assurance (PSQA) system to ensure the accurate delivery of treatment plans. The Delta 4 plus is the orthogonal diode arrays that enables providing 3D dose distribution and instantaneous analysis. Therefore, this study aims to evaluate the efficiency of the Delta4 plus for PSQA tool in Tomotherapy H at NCI. The detector was investigated for the basic dosimetric characteristic in terms of short-term reproducibility, response linearity, and dose rate dependence including effect of PTV size and location that simulated from clinical case. Moreover, the Delta4 plus response was also evaluated for the effect of the geometry planning parameters such as field width (FW), pitch, and modulation factor (MF). Finally, the retrospective of 30 patient’s plans (10 prostate cancers, 10 head and neck cancers, and 10 breast cancers) who were treated with Tomotherapy H at NCI were studied and the gamma passing rate (GP) results were compared to the MapCHECK2, which is the routine PSQA tool at NCI. The Delta4 plus response was stable within ± 0.37% for ten repeated measurements. The dose was linearly (R2 = 1) proportional to the clinical beam on times range of 10 to 1,000 secs. The Delta4 plus showed less dependence on the dose rate variation (600 – 1,000 MU/min) with the variation of response was within 0.3%. The Delta4 plus showed no different response for PTV sizes and locations with the average GP was greater than 90% using the gamma criteria of 3% 3mm (TG148). However, the effects were exhibited when using a strict criteria of 2% 2mm. The GP was decreased when the PTV size was increased and located far away from the detector’s center. For the effect of geometry planning parameters, the Delta4 plus response showed the average GP more than 95% (3% 3mm, criteria) and demonstrated no significant difference for various FWs, pitches, and MFs (p value > 0.05). For the clinical cases, the results of PSQA in each sites of cancer provided high average GP greater than 95% with gamma criteria of 3% 3mm. Moreover, the GP results of Delta4 plus was showed moderate correlation with MapCHECK2 measurement. In addition, in this study, we also evaluated the effect of CT-image data set using to create the DQA plans and found that there were no significant difference (p value > 0.05) for both of actual and virtual CT images sets. In conclusion, the Delta4 plus can be considered as a suitable and effective quality assurance tool for the DQA of Tomotherapy H at NCI. Implication of Thesis: The Delta4 Plus is suitable for use as a DQA tool in Tomotherapy due to its excellent dosimetric characteristics exhibited by the detector, less dependence on geometric plan parameters, and high gamma passing rate results. The detector's gamma passing rate results show a moderate correlation with the MapCHECK2, which is currently the routine DQA tool used in Tomotherapy. Additionally, the results demonstrate the superior performance of the Delta4 Plus in 3D gamma analysis for searching control points for the PTVs that are large and located off-axis, resulting in a higher passing rate compared to the 2D gamma analysis of the MapCHECK2. In conclusion, this study provides evidence that the Delta4 Plus can be used for routine PSQA in Tomotherapy at NCI.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.