Skip to content
Open access

Parameter-Dependent Effects of Spinal Cord Stimulation on Neural Activation and Evoked Compound Action Potentials

Aug 2026 · bioRxiv · 0 citations · 77 references
Biology

TL;DR

A hybrid computational modeling approach is employed, coupling finite element method models with multicompartment axon models with multicompartment axon models to simulate neural responses to SCS and demonstrate that the selection of recording electrodes can be optimized to enhance recorded ECAP amplitudes.

Abstract

Objective Spinal evoked compound action potentials (ECAPs) provide a quantitative measure of the neural response during spinal cord stimulation (SCS) and can be leveraged in closed-loop applications to control dose in response to spinal cord movement. However, interpretation of ECAPs recorded in vivo is limited by susceptibility to noise, inter-subject variability, and other confounding factors. As SCS systems evolve and the clinical and research applications of ECAPs expand, it is critical to understand how physiological and technical factors influence ECAP generation and morphology. Approach We used a computational modeling framework to systematically investigate the influence of anatomical (e.g., dorsal cerebrospinal fluid (dCSF) thickness), stimulation (e.g., pulse width, waveform shape, stimulation configuration, stimulation frequency), and recording configurations on the neural responses and ECAPs generated during SCS. We employed a hybrid computational modeling approach, coupling finite element method models with multicompartment axon models to simulate neural responses to SCS. Using these models, we characterized the spatiotemporal dynamics of neural recruitment and the resulting ECAP waveforms. Main results Neural responses and model ECAPs were strongly influenced by factors, such as dCSF thickness, pulse width, and stimulation waveform shape. Stimulation parameters introduced trade-offs between axonal recruitment thresholds, neural activation selectivity, and ECAP timing and morphology. Notably, similar ECAP amplitudes could obscure differences in the underlying neural recruitment. Complex ECAP morphologies also emerged in response to distinct stimulation paradigms, reflecting changes in the spatiotemporal properties of axonal activation. Additionally, we demonstrate that the selection of recording electrodes can be optimized to enhance recorded ECAP amplitudes. Significance Our findings provide a theoretical framework to advance our mechanistic understanding of SCS-induced ECAPs and offer insights into optimization strategies to improve closed-loop SCS therapies.

Read PDF

Similar papers

Review Aug 2026

Neuroplasticity in the spinal cord associated with transcranial direct current stimulation in health and disease: a perspective.

Transcranial direct current stimulation (tDCS) is a non-invasive neuromodulation technique widely used to modulate cortical excitability, yet its influence on spinal mechanisms remains less understood. This review synthesizes current evidence on the effects of tDCS on human spinal circuitry in both health and disease....

S. Grosprêtre, Markus Gruber, E. Amiri · 0 citations
Review Open access Aug 2026

Molecular and Cellular Mechanisms of Spinal Cord Stimulation: Linking Dorsal Horn Circuits, Glia, and ECAP-Guided Therapy

The need for multimodal experimental approaches to more precisely define how SCS achieves analgesia is underscored, underscoring the need for multimodal experimental approaches to more precisely define how SCS achieves analgesia.

Milan Patel, Alison J Deng, Ameya V. Belamkar et al. · 0 citations
Open access Sep 2026

Weak electric fields of deep brain stimulation can entrain spiking in multi-compartment cortical neuron models

C cortical E-fields of DBS may directly influence activity of some cortical neurons, alongside the established indirect cortical effects mediated by subcortical targets and their networks, according to a new perspective on how DBS may influence cortical activity.

Maud Bosman, Nina Doorn, H. G. Meijer et al. · 0 citations
Open access Sep 2026

A generalized activating function for rapid and accurate neural response prediction in spinal cord stimulation

We present the Generalized Activating Function (GAF), a biophysics-grounded framework that accelerates neural activation predictions by up to three orders of magnitude relative to NEURON simulations of multi-compartment cable models while maintaining high predictive accuracy ( R 2  = 0.99). By overcoming computa...

Taylor H. Newton, Javier García Ordóñez, Abdallah Alashqar et al. · 0 citations
Open access Aug 2026

Motor-evoked modules obtained from transcranial magnetic stimulation.

Findings indicate that stimulus intensity shapes the pattern-level structure of corticospinal outputs and suggest that MEMs obtained from TMS complement well-established single-muscle MEP analyses and offer a novel perspective for investigating the motor system.

T. Morishita, M. Coscia, Mirea Bacigalupo et al. · 0 citations
Review Open access Aug 2026

State of the Art in Neuromodulation or Spinal Cord Stimulation Therapy

Future progress in SCS will likely depend on artificial intelligence, remote monitoring, biomarker-guided programming, and integration with multidisciplinary chronic pain care.

Nafay Abdul, Milan Patel, Rohit Aiyer et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.