Dec 2026· Journal of Biomedical Physics and Engineering· Vol 16 6, pp.
483-494
· 3 citations· ⚡ 2 influential
Medicine
TL;DR
It is demonstrated that a simplified three b-value IVIM approach is clinically feasible for glioma grading and all derived parameters shows the potential of this simplified technique to provide valuable diagnostic information, reducing acquisition time and complexity while maintaining accuracy.
Abstract
Background
Intravoxel Incoherent Motion (IVIM) imaging shows promise for glioma characterization, but complex acquisition and analysis hinder its clinical use. Simplifying IVIM by using fewer b-values could improve feasibility. This study investigates a simplified three b-value IVIM approach for glioma grading.
Objective
To assess the diagnostic performance of a simplified IVIM model using three b-values and to analyze all derived quantitative parameters for glioma grading.
Material and Methods
This retrospective study analyzed IVIM data acquired from 30 glioma patients. A simplified model was implemented using b-values of 0, 200, and 1000 s/mm². In addition to routine IVIM parameters (D, f, D*), we calculated simplified parameters: D3b, f3b, D3b*, ADC0-200, ADC0-1000, ADC200-1000, and Simple Perfusion Fraction (SPF) for each region of interest (tumor, edema, and normal-appearing white matter). Correlations were assessed, and diagnostic performance was evaluated.
Results
Strong correlations were observed between simplified and routine IVIM parameters. The cancerous region was the optimal Regions of Interest (ROI) for grading. ADC200-1000, and SPF demonstrated superior diagnostic performance (the Area Under the Curve (AUCs) of 85.3% and 77.2%, respectively) compared to routine IVIM parameters.
Conclusion
This study demonstrates that a simplified three b-value IVIM approach is clinically feasible for glioma grading. Analyzing all derived parameters shows the potential of this simplified technique to provide valuable diagnostic information, reducing acquisition time and complexity while maintaining accuracy. Furthermore, ADC200-1000 has shown superior performance compared to conventional Apparent Diffusion Coefficient (ADC) ADC0-1000 in Diffusion-Weighted Imaging (DWI) with a more accurate representation of tissue diffusion characteristics, resulting in its replacement for conventional ADC.
The results are packaged in the Greenfield Startup Model (GSM), which explains the priority of startups to release the product as quickly as possible, and the need to shorten time-to-market, by speeding up the development through low-precision engineering activities.
Carmine Giardino, Nicolò Paternoster, M. Unterkalmsteiner et al.· IEEE Transactions on Softwar...· 178 citations· ⚡14
Software startup companies develop innovative, software-intensive products within limited timeframes and with few resources, searching for sustainable and scalable business models.
M. Unterkalmsteiner, P. Abrahamsson, Xiaofeng Wang et al.· e-Informatica Software Engin...· 157 citations· ⚡17
This study conducts a case survey study based on the secondary data of the major pivots happened in 49 software startups, and demonstrates that customer need pivot is the most common among all pivot types.
Sohaib Shahid Bajwa, Xiaofeng Wang, Anh Nguyen-Duc et al.· Empirical Software Engineeri...· 127 citations· ⚡15
The comparison of adopter and non-adopter sample reveals three potential adoption inhibitor, security, data privacy, and portability, which underlines the importance of the technical and security perspectives for research investigating the adoption of technology.
Nattakarn Phaphoom, Xiaofeng Wang, S. Samuel et al.· Journal of Systems and Softw...· 111 citations· ⚡8
Objective There is dearth of information on the timeliness of antenatal care (ANC) uptake. This study aimed to determine the timely ANC uptake by a medically trained provider (MTP) as per the World Health Organization (WHO) recommendations and the country guideline. Methods Cross-sectional survey was done with 2,731 wo...
B. Sarker, Musfikur Rahman, T. Rahman et al.· PLoS ONE· 89 citations· ⚡7
This study investigates how Lean internal startup facilitates software product innovation in large companies and identifies its enablers and inhibitors, and shows the potential of the method-in-action framework to investigate the Lean startup approach in non-startup context.
Henry Edison, Nina M. Smørsgård, Xiaofeng Wang et al.· Journal of Systems and Softw...· 78 citations· ⚡6
Related blog posts
MIT News · Artificial Intelligence· news.mit.eduNov 23, 2026
Senior Research Scientist Jim Glass discusses how his MIT-IBM Computing Research Lab collaboration connects perception and language, and addresses the shortcoming of current models.
MIT News · Artificial Intelligence· news.mit.eduNov 20, 2026
Enforcing physics-based constraints prevents AI models from generating unreliable predictions for complex nonlinear systems in weather, climate, and turbulent flows.